Section 1 Information And Requirements; Appliance Information - Flavel Orchestra Installation And Maintenance Instructions Manual

Coal effect balanced flue gas fire
Table of Contents

Advertisement

1.0

APPLIANCE INFORMATION

Main injector : (1 off)
Pilot Type :
Max. Gross Heat Input :
Min. Gross Heat Input :
Gas Rate :
Cold Pressure :
Ignition :
Electrode Spark Gap :
Weight (with fender) :
Fig 1
580mm
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS EN 613 : 2001 and the result is 74%.
The gross calorific value of the fuel has been used for this efficiency
calculation.
The test data from which it has been calculated has been certified by Advantica.
The efficiency value may be used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings.
SECTION 1
INFORMATION AND REQUIREMENTS
470mm
Stereomatic Injector Elbow – size 60 (NG)
S.I.T.140 Series
3.8 kW
2.5 kW
0.345 m 3 /hr – NG models
0.139 m 3 /hr – LPG models
20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
37.0+/-1.0 mbar (14.8 +/- 0.4 in w.g.)
Push-button Piezo
4.0mm
30.0 kg inclusive of flue pipe and terminal
150mm
50mm
3
size 19 (LPG)
NG – size 27
LPG - size 19
435mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fbfn76gFbfn98gFbfp76gFbfp98gOrchestra fbfn g seriesOrchestra fbfn76g ... Show all