Warning : Use only the pebbles supplied with the fire. When replacing the
pebbles remove the old pebbles and discard them. Fit a complete
set of pebbles of the correct type. Do not fit additional pebbles or
any pebbles other than a genuine replacement set.
To ensure that the release of fibres from these R.C.F (Refractory Ceramic
Fibre) articles is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust
accumulated in and around the appliance before and after working on the
appliance. When replacing these articles we recommend that the replaced
items are not broken up, but are sealed within heavy duty polythene bags,
clearly labelled as "RCF waste". RCF waste is classed as a "stable", non
reactive hazardous waste and may be disposed of at a landfill licensed to
accept such waste Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not
smoking, eating or drinking in the work area, and always wash your hands
before eating or drinking.
6.8.9
Replace the glass panel and retaining trims as described on
pages 71 & 72.
NEVER USE THE FIRE WITHOUT THE GLASS PANEL IN POSITION, OR IF
BROKEN OR CRACKED.
6.9
CLEANING THE FIRE - WARNING
CLEANING THE DECADENCE FASCIA'S AND PAINTED METAL
PARTS
Metal polishes must not be used on these fascia's. These should only be cleaned
using a clean, damp cloth. The Decadence fascia is best cleaned by removing it
from the fire and placing it face up on a flat surface.
Abrasive cleaners, chemical cleaning agents or any type of polish must
never be used as damage to the finish may result.
PLEASE NOTE :- The glass will require cleaning periodically. Condensation
produced by the products of combustion will create marks on the inside face of the
glass panel.