Information And Requirements; Appliance Information - Flavel Kenilworth Installation, Maintenance & User Instructions

Inset live fuel-effect gas fires
Table of Contents

Advertisement

1.0

APPLIANCE INFORMATION

Model
Gas Type
Main injectors (2 off)
Pilot Type
Max. Gross Heat Input :
Min. Gross Heat Input :
Cold Pressure :
Ignition :
Electrode Spark Gap
Weight
SECTION 1

INFORMATION AND REQUIREMENTS

FKPC**MN (MC)
FKPC**SN (SC)
FKPC**RN2 (RC)
G20
Size 260 (MC & SC) Size 85 (SC)
Size 280 (RC)
Copreci
21100 / 141 (MC)
21100 / 162 (SC)
ERTA OXYP (RC)
PG-83-10
6.9 kW
4.2 kW
20.0 mbar
+/-1.0mbar
Push Button Piezo (MC models)
1.5V Battery Generator (SC models)
4.5V Battery Generator (RC models)
4.5mm Nominal
See product packaging for individual model
weights
3
FKPC**SP (SC)
G31
21100 / 263 (SC)
6.9 kW
4.2 kW
37.0 mbar
+/-1.0mbar

Advertisement