INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Main injector : (1 off)
Pilot Type :
Max. Gross Heat Input :
Min. Gross Heat Input :
Cold Pressure :
Ignition :
Electrode Spark Gap :
Packed Weight Combustion Chamber : 28.0 kg
Fig 1.
Top View of Combustion
Chamber
SECTION 1
Bray Injector Cat 82 – size 500 (NG)
Copreci ODS 21100 / 141
6.9 kW
4.2 kW
G20
20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
Push Button Piezo
4.0mm
Side View of Combustion
Chamber
3