General information

Table of contents

Guarantee, safety

Main statutory instruments

Contents
Guarantee, safety .............................. 2
Main statutory instruments ................. 2
Overview legend................................. 3
Packaging........................................... 4
Technical data
See technical data N° 13013504
Assembly............................................ 5
Gas connection .................................. 6
Electrical connection .......................... 6
Preliminary check-up.......................... 7
Settings ..................................... 7 to 13
Control panel TC .............................. 16
Settings, safety checks..................... 17
Firing ................................................ 17
Maintenance.................................... 18
Troubleshooting ............................. 19
2
Guarantee
Installation and start up must be carried
out in accordance with currently
accepted practices by a qualified
technician; current regulations as well as
the instructions that follow must be
complied with.
The manufacturer will decline all
responsibility in the event of failure to
comply fully and in every respect with
any of the relevant requirements.
Refer also to:
- the certificate of guarantee attached to
the burner;
- the general terms of sales.
Safety
The burner is designed to be installed on
a generator connected to exhaust pipes
used for products of combustion in
serviceable condition.
It should be used in areas where an
adequate supply of fresh air is available
for correct combustion and where any
waste products can be properly
evacuated.
The size and design of the flue must be
appropriate to the fuel in accordance
with current regulations and standards.
Power supply 230 VAC % 50Hz
+10
- 15
the control and safety unit as well as to
the cut-off devices used must include an
earthed neutral wire.
In addition, the neutral conductor
must have the same electrical
potential as the earth conductor.
Failing that, power supply to the burner
must include an isolating transformer
and the appropriate protection (30 mA
circuit breaker and fuse).
In order that the burner operates
correctly, please respect the polarity
of the conductors when connecting
the 7P connector.
The burner must be able to be isolated
from the system by means of
a multi pole switch complying with the
standards in force.
Operating personnel should act with
extreme caution in all cases and more
especially avoid any direct contact with
areas that are not heat-insulated and
electrical circuits.
Water should not be splashed on to the
burner's electrical components.
In the event of flooding, fire, fuel leakage
or any other dangerous situation
(smells, suspicious noises, etc.), stop
the burner, cut off the main power supply
and the fuel supply and call in an
approved specialist.
The use of chlorinated solvents to clean
the burner is prohibited.
It is compulsory for all furnaces and
accessories, flues and connection
pieces to be maintained, cleaned and
swept at least once a year and prior to
burner start up. Consult the applicable
regulations in force.
05/2008 - Art. Nr. 13 013 503D
Use a purpose-designed foam to test the
external tightness of valve assembly
connections, including the filter.
Main statutory instruments "FR"
Dwellings :
- French Order dated 2nd August 1977
and later modifying / supplementary
orders: Technical and safety
regulations governing combustible
gas and liquified hydrocarbon
installations located inside dwellings
and their outbuildings.
- DTU Standard P 45-204 : Gas
installations (formerly DTU n° 61-1
- Gas installations - April 1982 + later
addendums).
- DTU Standard 65.4 - Boiler house
technical provisions.
- French NF Standard C15-100 + Low
voltage electrical installation
regulations.
- French Departmental health
regulations.
Public Buildings :
- Public building fire and panic
prevention safety regulations.
General provisions :
±1%
- GZ sections (combustible gas and
liquified hydrocarbons);
- CH sections (heating, ventilation,
cooling, air conditioning and steam
and domestic hot water production);
Provisions specific to each type of public
building.
Outside "FR"
Refer to local regulations.