Start-up
Description and settings
VGD gas valve
SKP75 regulator
The VGD valve associated with
SKP75 regulator ensures a constant
gas flow/air flow ratio and is quick-
acting. The regulator also takes into
account combustion chamber pF
pressure.
The valve is delivered preset according
to table here below.
Burner C 285 GX 507/8
Gaz
P
VGD
40.065 40.08
(Screw R)
G20 20 - 40
(Screw D)
Burner C 330 GX 507/8
Gaz
P
VGD
40.065 40.08
(Screw R)
40
(Screw D)
G20
(Screw R)
150
(Screw D)
Burner C 380-430 GX 507/8
Gaz
P
VGD
40.065 40.08
(Screw R)
G20
150
(Screw D)
12
1
2
2
1,4
2
1,4
1
2
R ratio
indicator
1
2
05/2008 - Art. Nr. 13 013 503D
1
Pressure switch electrical
connection (DIN 43650)
2
Solenoid electrical connection
(DIN 43650)
3
Pressure switch
4
Intake flange
5
Pressure take-off G 1/8 before the
filter
6
External filter DN65
7
Identification plate
8
Air pressure pL G 1/8 connection
9
Adjusting screw R of gas flow/air
flow ratio
12
Adjusting screw D for correcting
zero point
13
Connection G 1/8 for combustion
chamber pressure pF
14
Connection G 1/8 for gas
pressure pBr
15
Outlet flange
16
pBr - pL - pF pressure take-off
pipes
Setting gas pressure switch
• Remove transparent cover.
Unit includes a
movable graduated disk.
• Provisionally set the pressure
switch at the minimum value
shown on the graduated disk.
Gas valve
opening
indicator
D value
indicator
|
index and a

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 330C 380C 430 gx 507/8

Table of Contents