ROOM SEALED (TYPE C) FLUE ASSEMBLY

In order to install the EcoKnight™ water heater with a type C (room sealed) flue system a flue transition kit must first be installed,
this kit is used for both C
(horizontal) and C
13
kits and their installation

INSTALLATION OF TRANSITION KIT TO EKW116CE WATER HEATERS

10.8.1
FIGURE 9.2
10.8.2
Depending upon the flue kit chosen either a vertical or horizontal concentric terminal will be included in
the packaging with the transition kit, additional elbows, flue lengths etc. Are available as ancillary items.
Additional wall brackets may be required to ensure the flue system is stable.
For a full list of flue components supplied and optional parts to complete the system see the EcoKnight™
flue guide available at
ITEM NUMBER
1
2
3
4
5
6 (a)
6 (b)
6 (c)
1.1.1
FLUE TRANSITION PARTS EKW86CE – EKW116CE
(vertical) flue systems. The information in this paragraph describes these flue transition
33
FLUE TRANSITION PARTS EKW116CE
www.Lochinvar.ltd.uk
DESCRIPTION
90⁰ ELBOW
45⁰ ELBOW
SAMPLING POINT
CONCENTRIC ADAPTOR
AIR INTAKE TRANSITION
100mm X 500mm LENGTH
100mm X 500mm LENGTH
100mm X 500mm LENGTH
EKW/EKW 86
3 REQUIRED
1 REQUIRED
1 REQUIRED
1 REQUIRED
1 REQUIRED
KEEP 500mm
CUT TO 330mm
CUT TO 330mm
EKW/EKW 116
3 REQUIRED
1 REQUIRED
1 REQUIRED
1 REQUIRED
1 REQUIRED
KEEP 500mm
CUT TO 330mm
KEEP 500mm
23