Lochinvar ECOKNIGHT EKW116CE Installation, Commissioning, Maintenance And User Instructions page 75

Floor standing gas fired condensing circulating type water heater
Table of Contents

Advertisement

19.2.4
EKW146CE
1.
Remove the top and front access covers from the unit (no tools required for removal).
2.
Remove the gas valve and manifold from the unit via the unions on each end.
3.
Remove the three screws mounting the injector plate on the air shroud.
4.
Remove the four screws securing the manifold adapter to the injector plate taking care not to damage the O-ring.
5.
Locate the propane orifice disk from the conversion kit bag. Verify that the stamping on the orifice disk is correct for the
water heater
see 18.2.1.
6.
Remove the existing orifice from the O-ring in the side of the injector plate and replace it with the orifice from the kit.
Position and secure the orifice in the injector plate as shown.
7.
Reposition the manifold adapter to the injector plate and replace the four manifold adapter mounting screws. Handle the
O-ring with care, do not damage.
8.
Reposition the injector plate to the air shroud and replace the three injector plate mounting screws.
9.
After installation is complete, attach the propane conversion label (in the conversion kit bag) next to the water heater rating
plate. Attach the LPG caution label (in the conversion kit bag) to the left side of the unit in the lower left corner.
10.
Replace the top and front access covers.
19.2.5
CONVERSION PROCEDURE EKW14CE
75