19.2.6
EKW176CE – EKW236CE
1.
Remove the top and front access covers from the unit (no tools required for removal).
2.
Remove the four screws and nuts that hold the adaptor flange to the inlet of the venturi.
3.
Separate the flange and venturi ensuring the gasket is not damaged.
4.
Locate the propane orifice disk from the conversion kit bag. Verify that the stamping on the orifice disk is correct for the
water heater
see
18.2.1.
5.
Fit the orifice plate ensuring its correct orientation (see DETAIL A)
6.
Reinstall the four screws and nuts holding the adapter flange to the inlet of the venturi ensuring the correct location of the
gasket.
7.
After installation is complete, attach the propane conversion label (in the conversion kit bag) next to the water heater rating
plate. Attach the LPG caution label (in the conversion kit bag) to the left side of the unit in the lower left corner.
8.
Replace the top and front access covers.
19.2.7
CONVERSION PROCEDURE EKW176CE – EKW236CE