Rear Vent Configuration with Vertical Termination

Use the rear vent conversion from
Travis Industries (SKU 94400998).
Use 8" Diameter Vent
Horizontal sections require a ¼"
(6mm) rise every 12" (305mm) of
travel.
A maximum of three (3) 45° or 90°
elbows may be used. Of these
elbows, only one (1) may be a
horizontal elbow (see illustration).
The termination must fall within the
shaded area shown in the chart.
Use the indicated restrictor position.
NOTE: Restrictor positions are
based upon lab tests. The ideal
restrictor position may vary slightly,
especially when the termination is
near a demarcation line.
Diffuser must be closed (see page
14).