Gas Line Installation; Gas Inlet Pressure - Lopi Greenfield GSR2 Manual

Table of Contents

Advertisement

Installation

Gas Line Installation

The gas line must be installed in accordance with all local codes and the requirements listed
below. In the absence of local codes, follow ANSI 223.1 in US/Canada or AS/NZS 5601.1 in
Australia.
!
The heater and gas control valve must be disconnected from the gas supply piping during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPA). For pressures
under 1/2 psig (3.45 kPA), isolate the gas supply piping by closing the manual shutoff valve.
This heater is designed for natural gas but can be converted to propane. Check the sticker on
top of the gas control valve to verify the correct fuel is used (see page 4).
Leak test all gas line joints and the gas control valve prior to and after starting the heater.
The location of the gas inlet is shown below
A manual shutoff valve is required for installation (it must be located within 3' of the heater).
T-Handle gas cocks are required in Massachusetts in compliance with code 248CMR.
This stove is shipped with a 18" long, 3/8" diameter flex gas line attached to an elbow on the gas
control valve that is routed to the rear left of the appliance (see illustration below). It protrudes
approximately 4" from the rear of the stove. The flex accepts a 3/8" flare fitting.

Gas Inlet Pressure

Max. Input Pressure
Gas Pressure
7" W.C. (1.74 kPA)
Natural Gas
13" W.C. (3.23 kPA)
Propane
If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is
adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.
The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank)
should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the
regulator is at an improper pressure.
© Travis Industries
(for qualified installers only)
Min. Input Pressure
Max. Manifold Pressure
5.5" W.C. (1.37 kPA)
11" W.C. (2.74 kPA)
2/23/18 - 1479
Min. Manifold Pressure
3.5" W.C. (0.87 kPA)
11" W.C. (2.74 kPA)
Greenfield GSR2-Aust
11
1.6" W.C. (0.40 kPA)
2.9" W.C. (0.72 kPA)