Chimney Termination Requirements; Outside Air Requirements - Lopi Republic 1750 Owner's Manual

Table of Contents

Advertisement

12
Stove Installation

Chimney Termination Requirements

Must have an approved cap (to prevent water from entering)
Must not be located where it will become plugged by snow or other material
Must terminate at least 3' (914mm) above the roof and at least 2' (610mm) above any portion of the
roof within 10' (3.04M) - see Figure 6 below.
Min. 3' (914mm)
Min. 3' (914mm)

Outside Air Requirements

Required for mobile homes & in certain localities (check with building officials).
May be drawn from a ventilated area (crawl space, etc. - check with building officials).
Must not be drawn from an enclosed space (garage, unventilated crawl space).
Requires the optional outside air kit or boot.
Air duct maximum length is 15' (4.57M) with a minimum cross-section of 16 square inches
(10404mm) or 6' (1.82M) with a minimum cross section of 7 square inches (4489mm).
© Travis Industries
(for qualified installers only)
Outside Air
Connector
Outside air entrance must be placed so
it does not become blocked by snow.
100-01433
Min. 2' (610mm)
10' (3.04M)
Min. 2' (610mm)
10' (3.04M)
Figure 6
4151217