Safety; Intended Use - Pilz PSEN sl-1.0p 3.1 Operating Manual

Hide thumbs Also See for PSEN sl-1.0p 3.1:
Table of Contents

Advertisement

PSEN sl-1.0p 3.1

Safety

Intended use

Safety function of safety switch:
}
2 safety outputs supply a high signal each when the corresponding input is high and the
actuator is in the switch's response range.
The safety gate system meets the requirements in accordance with
}
EN 60947-5-3: PDDB with the corresponding actuator PSEN sl0.5 or PSEN sl0.5fm
(see Technical details:
actuator [
}
EN 62061: SIL CL 3
}
EN ISO 13849-1: PL e and Cat. 4
}
EN ISO 14119: Coding level Low, Type 4
}
The safety switch may only be used with the corresponding actuator (see Technical De-
tails:
actuator [
The safety level PL e (Cat. 4 )/SIL CL 3 is only achieved if
}
the safety outputs use 2-channel processing.
Because of the low operating distance (see
curacy of 40 % deviates from the requirement in accordance with EN 60947-5-2 (max.
10%).
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the product
}
Use of the product outside the areas described in this manual
}
Use of the product outside the technical details (see
Operating Manual PSEN sl-1.0p 3.1
1003389-EN-04
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
System with normal actuator [
28])
System with normal actuator [
28]).
NOTICE
Positioning of the safety switch
As the safety switch is not intended for a guard locking device for personal
protection, the safeguard monitored by the safety switch must be positioned
in a way that the access time corresponds at least to the machine's stop-
ping time.
25],
System with free-moving
25],
System with free-moving
Technical details [
Technical details [
25]) the repetition ac-
25]).
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

570670570673

Table of Contents