Dalsa Falcon 4-CLHS Series User Manual page 76

Hide thumbs Also See for Falcon 4-CLHS Series:
Table of Contents

Advertisement

Gain
Exposure Time
Exposure Delay
ROI Selector
ROI Offset Y
Line Selector
Line 3
Line 4
Line 5
Line 6
Output Line Source
Off
Pulse On: Start of
Exposure
Pulse On: End of Timer 1
Pulse On: End of Counter 1
Pulse On: Input 1
Pulse On: Input 2
Software Controlled
Pulse On: CLHS In
Exposure Active
Output Line Value
Active
Inactive
74  Operational Reference
cP_DigitalGain
Sets the selected gain as an amplification factor applied to
the image. This gain is applied when the current Cycling
index is active.
cP_ExposureTime
Sets the exposure time, in milliseconds. Applicable only
when the Exposure Mode feature is set to Timed. This
setting will be applied when the current Cycling index
occurs.
cP_ExposureDelay
Sets the exposure delay (in microseconds) for the selected
set.
cP_MultiROISelector
Select an ROI (Region of Interest) when Multiple ROI Mode
is enabled. Selector range is from 1 to the Multiple ROI
Count Vertical value, or maximum 8 if Multiple ROI Count
Vertical is greater than 8. The height of each ROI is from
Multi ROI Height on Image Format page. Smaller ROI ID has
smaller OffsetY.
cP_MultiROIOffsetY
Vertical offset (in pixels) from the origin to the selected ROI
(Region of Interest).
cP_LineSelector
Cycling Preset Line Selector.
Line3
Index of the physical line and associated I/O control block to
use. Pin 6 is the Output Signal and Pin 4 is the common
output power on the I/O connector.
Line4
Index of the physical line and associated I/O control block to
use. Pin 8 is the Output Signal and Pin 4 is the common
output power on the I/O connector.
Line5
Index of the physical line and associated I/O control block to
use. Pin 9 is the Output Signal and Pin 4 is the common
output power on the I/O connector.
Line6
Index of the physical line and associated I/O control block to
use. Pin 10 is the Output Signal and Pin 4 is the common
output power on the I/O connector.
cP_OutputLineSource
Selects what to output on the selected output line.
Off
Line output is disabled (Tri-State) or Open with Optocoupled
output.
PulseOnStartofExposure
Generate a pulse on the ExposureStart event.
PulseOnEndofTimer1
Generate a pulse on the end of timer1.
PulseOnEndofCounter1
Generate a pulse on the end of Counter1.
PulseOnInput1
Generate a pulse on the Input Signal 1 event.
PulseOnInput2
Generate a pulse on the Input Signal 2 event.
SoftwareControlled
The OutputLineValue feature changes the state of the
output.
PulseOnLinkTrigger0
Generate a pulse on LinkTrigger0 signal.
ExposureActive
Generate the Exposure Active state on specific output.
cP_OutputLineValue
Cycling Preset Output Line Value.
Active
Active sets the output circuit to closed.
Inactive
Inactive sets the output circuit to open.
1.02
Expert
DFNC
1.02
Expert
DFNC
1.02
Expert
DFNC
1.02
Expert
DFNC
1.02
Expert
DFNC
1.02
Expert
DFNC
1.02
Expert
DFNC
1.02
Expert
DFNC
Falcon™ 4-CLHS Series

Advertisement

Table of Contents
loading

Table of Contents