Dalsa Falcon 4-CLHS Series User Manual page 70

Hide thumbs Also See for Falcon 4-CLHS Series:
Table of Contents

Advertisement

Counter Reset Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Value
Counter Value at Reset
Counter Reset
Timer Selector
Timer 1
Timer Mode
Off
Active
Timer Status
Timer Idle
Timer Trigger Wait
Timer Active
Timer Completed
Timer Start Source
TimerReset Cmd
Exposure Start
ExposureEnd
Readout Start
Readout End
Frame Start
Valid Frame Trigger
Frame Start
Frame Burst End
Line 1
Line 2
CLHS In
Timer 1 End
Counter 1 End
Timer Line Activation
Rising Edge
Falling Edge
Any Edge
Timer Delay
68  Operational Reference
counterResetLineActivation
RisingEdge
FallingEdge
AnyEdge
counterValue
counterValueAtReset
counterReset
timerSelector
Timer1
timerMode
Active
timerStatus
TimerIdle
TimerTriggerWait
TimerActive
TimerCompleted
timerStartSource
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
ValidFrameTrigger
FrameStart
FrameBurstEnd
Line1
Line2
LinkTrigger0
Timer1End
Counter1End
timerStartLineActivation
RisingEdge
FallingEdge
AnyEdge
timerDelay
Specify the edge transition on the selected line that will
reset the selected counter.
Reset counter on rising edge of the selected signal.
Reset counter on falling edge of the selected signal.
Reset counter on the falling or rising edge of the selected
signal
Read the current value of the selected counter.
Stores the counter value of the selected counter when it
was reset by a trigger or by an explicit Counter Reset
command.
Resets the selected counter to zero. The counter starts
immediately after the reset. To temporarily disable the
counter, set the Counter Start Source feature to Off.
Selects which timer to configure.
Timer 1 selected
Select the Timer mode. The selected Timer is Active or
Disabled. When Disabled, the Timer can be configured.
Off
The selected Timer is Disabled.
The selected Timer is Enabled.
Returns the current state of the timer.
The timer is idle. The TimerStartSource feature is
set to off.
The timer is waiting for a start trigger.
The timer is counting for the specified duration.
The timer reached the TimerDuration count.
Select the trigger source to start the timer. The
Control section
provides details and timing diagrams for
the supported events.
Off
Starts with the reception of the TimerReset Icommand.
Start Timer on Exposure Start event.
Start Timeron Exposure End event.
Start Timer on Readout Start event.
Start Timer on Readout End event.
Start Timer on Frame Start event.
Start Timer on Valid Frame Trigger.
Start Timer on Frame Start event.
Start Timer on Frame Burst End event.
Start Timer on a transition of I/O Line 1 event.
See Input Signals Electrical Specifications.
Start Timer on a transition of I/O Line 2 event.
Start Timer on a transition of CLHS In (LinkTrigger0).
Start Timer on Timer End event.
Start Timer on Counter 1 End event.
Select the trigger activation mode which starts the timer.
Starts counter on rising edge of the selected signal.
Starts counter on falling edge of the selected signal.
Starts counter on the falling or rising edge of the
selected signal.
Sets the duration (in microseconds) of the delay to apply at
the reception of a Start Trigger before starting the timer.
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Event
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
Falcon™ 4-CLHS Series

Advertisement

Table of Contents
loading

Table of Contents