Counter Incremental
Source
Off
Exposure Start
ExposureEnd
Readout Start
Readout End
Frame Start
Valid Frame Trigger
Frame Burst
CLHS In
Line 1
Line 2
Invalid Frame Trigger
Internal Clock
Timer 1 End
Counter Incremental Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Duration
Counter Reset Source
Off
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Valid Frame Trigger
Invalid Frame Trigger
FrameBurst End Trigger
Line 1
Line 2
CLHS In
Timer 1 End
Counter 1 End
Falcon™ 4-CLHS Series
counterIncrementalSource
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
ValidFrameTrigger
FrameBurstEnd
LinkTrigger0
Line1
Line2
InvalidFrameTrigger
InternalClock
Timer1End
counterIncrementalLineActivation
RisingEdge
FallingEdge
AnyEdge
counterDuration
counterResetSource
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
ValidFrameTrigger
InvalidFrameTrigger
FrameBurstEnd
Line1
Line2
Link0Trigger
Timer1End
Counter1End
Select the event source which increments the counter. The
Event Control section
provides details and timing diagrams
for the supported events.
Off
Counter is stopped.
Counts the number of Exposure Start events.
Counts the number of Exposure End events.
Counts the number of Readout Start events.
Counts the number of Readout End events.
Counts the number of Frame Start events.
Counts the number of Valid Frame Triggers.
Counts the number of multi-frame end triggers.
Counts the number of transitions on LinkTrigger0.
Counts the number of transitions on Line 1 (based on the
counterIncrementalLineActivation feature setting)
See Input Signals Electrical Specifications.
Counts the number of transitions on Line 2 (based on the
counterIncrementalLineActivation feature setting)
Counts the number of rejected frame triggers.
The counter increments on each microsecond tick of the
device internal Clock.
Counts the number of Timer 1 End events.
Selects the counter signal activation mode. The counter
increments on the specified signal edge or level.
Increment the counter on the rising edge of the selected
I/O Line.
Increment the counter on the falling edge of the selected
I/O Line.
Increment the counter on the falling or rising edge of the
selected I/O Line.
Sets the duration (or number of events) before the
CounterEnd event is generated.
Selects the signal source to reset the counter. After a reset
the counter waits for the next countStartSource signal or
event.
Off
Reset on reception of the Reset Icommand.
Reset on reception of the Exposure Start event.
Reset on reception of the Exposure End event.
Reset the counter on the reception of the Readout Start
event.
Reset the counter on the reception of the Readout End
event.
Reset on reception of the Frame Start.
Reset on reception of the Valid Frame Trigger.
Reset on reception of the Invalid Frame Trigger.
Reset on reception of the Frame Burst end.
Reset counter on the specified transition on line 1.
See Input Signals Electrical Specifications.
Reset counter on the specified transition on line 2.
Reset on reception of CLHS In (Link0Trigger).
Reset on reception of the Timer End.
Reset on the reception of the Counter end.
Operational Reference  67
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC