SMC Networks HRR050-A 20 Series Operation Manual page 55

Thermo-chiller
Hide thumbs Also See for HRR050-A 20 Series:
Table of Contents

Advertisement

Communication setting menu
COmm
 MENU
MENU
▲/▼
▲/▼
RmT
ASC
Serialprotocol
DOUT2 ⇔ SEL
OUT2
PROT
▲/▼
▲/▼
A
485
Communicationsp
ecifications
TYPE
DOUT2 ⇔ TYPE
OUT2
▲/▼
▲/▼
OFF
AL01
RS-485terminal
TERM
DOUT2 ⇒ ALARM ⇒ CODE
OUT2
▲/▼
▲/▼
1
mT01
Slaveaddress
SLAVE
DOUT2
OUT1
SLV ⇔ ADDR
▲/▼
▲/▼
192
ALm
Communication speed
SPEED
 OUT3
DOUT3 ⇔ SEL
▲/▼
▲/▼
B
Contact input signal 1
OFF
function selection
DOUT3 ⇔ TYPE
OUT3
DIN1 ⇔ SEL
DINI
▲/▼
▲/▼
AL01
ALT
Contact input signal 1 type
DOUT3
OUT3
DIN1
INP1
⇒ SW ⇒ TYPE
▲/▼
▲/▼
Contact inputsignal 1
mT01
A
operation
DOUT3
OUT1
DIN1
INP1
⇒ CON ⇒ TYPE
▲/▼
▲/▼
Contact input signal 2
OFF
function selection
DIN2 ⇔ SEL
INP2
▲/▼
ALT
Contact input signal 2 type
DIN2
INP2
⇒ SW ⇒ TYPE
▲/▼
Contact input signal 2
A
operation
DIN2
INP2
⇒ CON ⇒ TYPE
▲/▼
Contact output signal 1
RUN
function selection
DOUT1 ⇒ SEL
OUT1
▲/▼
Contact output signal 1
A
operation
DOUT1 ⇒ TYPE
OUT1
▲/▼
Contact output signal 1
AL01
selected alarm
DOUT1
OUT1
⇒ ALARM ⇒ CODE
▲/▼
Contact output signal 1
mT01
Selective Maintenance
DOUTI⇒ MANT ⇒ CODE
DIN1
▲/▼
HRR Series
Reset menu
RST
MENU
▲/▼
Contact output signal 2
NO
Setting date reset
function selection
ALL ⇔ RESET
MODE
▲/▼
Contact output signal 2
Reset pump operation
NO
operation
time
PUMPT ⇒ RESET
PROT
▲/▼
Contact output 2
Resetting compressor
NO
selected alarm
operation time
COMPT ⇒ RESET
PROT
▲/▼
Fan operation time
Contact output 2
NO
reset *1
selected maintenance
⇒ MANT ⇒ CODE
FANT ⇒ RESET
PROT
▲/▼
Contact output signal 3
Dustproof filter usage
NO
function selection
time reset *1
FLTRT ⇒ RESET
PROT
▲/▼
Contact output signal 3
DI filter use time reset
NO
operation
*2
DIT ⇒ RESET
▲/▼
Contact output signal 3
Forced opening of solenoid
OFF
selected alarm
valve for DI *2
⇒ ALARM ⇒ CODE
DI ⇒ VALVE
▲/▼
Contact output 3
selected maintenance
⇒ MANT ⇒ CODE
When you press " ENT " key, chiller
energizing time at alarm occurrence
AL10
Fig 5-4 Key operation (4/4)
Chapter 5 Display and Setting of Various Functions
Information moniter menu
INFO
MENU
MENU
MENU
▲/▼
hRR
Model
018-R
▲/▼
20-
Power Options
DMTU
▲/▼
standard product/
STD
special numbers
WS001
SELIAL.NO
▲/▼
0000
Program number
PGNO
▲/▼
00
Program version
PGVER
▲/▼
0
Operation time
RUNT
▲/▼
0
Pump operation time
PUMPT
▲/▼
compressor
0
operation time
COMPT
▲/▼
0
Fan operation time
*1
FANT
▲/▼
Accumulated operation time
0
of the dust-proof filter *1
FLTRT
▲/▼
0
Accumulated operation
time of the DI filter *2
DIT
▲/▼
Number of times of
0
momentary power failure*5
POWF
▲/▼
Serial communication status
0000
DIT
COMM ⇒ STUS
▲/▼
is displayed.
MENU
Chiller energizing time at alarm accurrence is displayed
123
Alarm occurrence number
NO2
ENT
HRX-OM-X071
Alarm history menu
ALmh
nnn
MENU
Example
▲/▼
AL17
Alarm
(The latest)
▲/▼
AL10
Alarm
▲/▼
ALNN
Alarm
(The oldest)
*1:For air-cooled type.
*2:With electric conductivity
control function only.
*3 In the case of option Z, Z1, non-display.
*4 In the case of option Z non-display.
*5 For 200V type only.
5.2 Function
5-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hrr050-a 40 seriesHrr050-w 20 seriesHrr050-w 40 series

Table of Contents