  • Page 1 Installation Manual Inter-M P.A Convergence System IPC SYSTEM...
  • Page 2 A personal welcome to you from the management and employees of Inter-M All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
  • Page 3: Table Of Contents

    RJ45 Connector for Protection of Data ..................36 Application ............................37 T o setup SETUP PROGRAM ......................38 Setup to SM -100 touch screen focus ..................49 Checkpoints before using system .....................51 Service Procedures............................52 Schematic .............................52 Parts List ............................52 Variations and Options .......................52 Warranty ............................52 IPC SYSTEM...
  • Page 4: Unpacking

    Please take a few minutes to read this manual to familiarize yourself with important information regarding installation, product features, and operation. As with most electronic devices, O RIGIN AL PACKAGIN G (O R EQ UAL) IS REQ UIRED in the unlikely event that the product needs to be returned for servicing. IPC SYSTEM...
  • Page 5: Installation

    - DO N O T O PEN THE CASE O R ATTEMPT REPAIRS O R MO DIFICATIO N S YO URSELF This product contains no user-serviceable parts. Refer all maintenance to qualified Inter-M service personnel. O pening the case and/ or tampering with internal circuitry voids the warranty.
  • Page 6: Description

    Description IPC System i s a P.A system consi sti ng of 5 total equi pment and 3 programs. Consi deri ng user’ s convenience, LCD touch monitor was adopted, and connection was done with a single line of Category5 to promote convenience in construction.
  • Page 7: Design Of System

    In case of concentrated design method, appropriate method for a small size of buildings. - Decentralized Main Building A-Building B-Building Floor Floor Floor In case of distributed design method, designed so that the main building can perform concentrated method of broadcasting where there are many buildings. IPC SYSTEM...
  • Page 8: Feature

    64-CH emergency contact broadcasting and macro function provided for emergency broadcasting - M ON ITORIN G FUN CTION Enable to moni tor real-ti me broadcasti ng status of each zone and broadcasti ng status of 6 -w ay broadcasting. IPC SYSTEM...
  • Page 9: Front Panel

    (W here many SP-100 units are connected with this unit, a red LED turns on if one of SP-100 units is failed.) 7. USB PORT This is an USB port for connecting external storage unit. USB 2.0 supported. IPC SYSTEM...
  • Page 10: Rear Panel

    Th i s i s a j a ck f o r a ud i o i n p ut o f p er i p h er a l d evi ces such a s CD/ TUN ER/ DECK. 4) TRIM VO LUME Adjusting a Trim Volume enables to control MIC and AUX input level. IPC SYSTEM...
  • Page 11 This is a terminal to connect the SP-100. 14. FIRE EM ERGEN CY CON TACT TERM IN AL This is a fire emergency contact input terminal to perform emergency broadcasting to the setup zone where fire occurs. Up to 64 channels can be setup. IPC SYSTEM...
  • Page 12: Block Diagrams

    IN TER-M P.A CO N VERGEN CE SYSTEM Block Diagrams (SI-100) Block Diagrams (SI-100) IPC SYSTEM...
  • Page 13: Specifications

    +5°C ~ +40°C Power Source 100–120VAC or 220–240VAC; 50/ 60Hz Power Consumption W eight (SET) 11kg/ 24.2lb Dimensions (SET) 482(W ) x 176(H) x 380(D)mm/ 19(W ) x 6.5(H) x 15(D)in * Specifications and design subject to change without notice. IPC SYSTEM...
  • Page 14: Front Panel

    This is a switch to setup menu to control status of the monitor. 7. M ON ITORIN G SPEAKER This is a speaker that broadcasting comes from when monitoring input sound source or broadcasting status in the selected zone. IPC SYSTEM...
  • Page 15 16. 15 IN CH LCD TOUCH SCREEN It is possible to control and check current operation status of the system with a 15inch LCD monitor. A touch screen function is provided, which enable to simply operate the system with a keyboard or mouse. IPC SYSTEM...
  • Page 16: Rear Panel

    This is a terminal to receive power from a DC +12V adaptor. Connect the terminal after checking power. 6. MON ITOR TABLE This is a table for supporting SM-100 if installing a monitor on tables etc. without mounting it on a rack for use. Separately sold) IPC SYSTEM...
  • Page 17: Specifications

    Contrast Ratio 450 : 1 O perating Temperature -10°C ~ +40°C Power Source DC 12V, 3.5A Power Consumption W eight (SET) 6.5kg/ 14.3lb Dimensions (SET) 482(W )x310.5(H)x60(D)mm/ 19(W )x12.2(H)x2.4(D)in * Specifications and design subject to change without notice. IPC SYSTEM...
  • Page 18: Feature

    Fault LED of CH5 and CH6 lights on in occurrence of failure of CH5 or CH6 Fault. N ote : 2) A red LED lights on only when output of the AMP is more than 11W in short of the output terminal. IPC SYSTEM...
  • Page 19: Rear Panel

    INTER-M P.A CONVERGENCE SYSTEM Rear Panel (SP-100) Rear Panel (SP-100) 1. LOCAL INPUT This is an input Jack of MIC and Line Level. According to the Local input volume, XLR input is -60dBV through -16dBV, while Phone input is -43dBV through 0dBV.
  • Page 20 INTER-M P.A CONVERGENCE SYSTEM 4. INPUT CONTACT This sets up 6 operations in the Setup Mode of SI-100. 5. SPEAKER OUTPUT TERMINAL This is an output terminal of 6CH AMP. Caution : Take care of connecting terminals so that impedance of a speaker terminal may not become lower than specified 167 /100V(81.7...
  • Page 21: Rj45 Connector For Protection Of Data

    O 2 @ @ @ @ W @ 0 Y @ V 4 @ @ X ? @ @ @ @ 6 K ? O 2 0 M g @ @ the IPC System. ? J @ @ @ @ @ @...
  • Page 22: Block Diagrams

    IN TER-M P.A CO N VERGEN CE SYSTEM Block Diagram (SP-100) Block Diagram (SP-100) IPC SYSTEM...
  • Page 23: Specifications

    -10°C ~ +40°C Power Source 100–120VAC or 220–240VAC; 50/ 60Hz Power Consumption (1/ 8W Power O utput) 105W W eight (SET) 13kg/ 28.6lb Dimensions (SET) 482(W )x88(H)x380(D)mm/ 19(W )x3.5(H)x15(D)in * Specifications and design subject to change without notice. IPC SYSTEM...
  • Page 24: Feature

    - M ON ITORIN G FUN CTION You can listen to sound source at the actual broadcasting zone from the front speaker of this unit. - EXTERN AL AUX FUN CTION Mixing of external sound source is available as BGM in MIC broadcasting. IPC SYSTEM...
  • Page 25: Front Panel

    Press the switch to select the zone when monitoring announcement to each zone. (Monitoring done for only a zone) 7. TALK ON / OFF switch Press the switch to broadcast and if broadcasting is completed, press the switch once again (somewhat lengthily) to end. IPC SYSTEM...
  • Page 26 - 24 basic keypads are mounted as 1:1 response keypad on the output channel of SP-100 in each zone. Broadcasting can be done in 160 zones by adding up to 12 zones in use of the expansion keypad unit (SR-100KP). IPC SYSTEM...
  • Page 27: Rear Panel

    O FF O FF O FF O FF O FF CHIME SEL O FF O FF O FF (O N / O FF) O FF O FF O FF O FF O FF O FF O FF O FF IPC SYSTEM...
  • Page 28 This terminal is used to broadcast external sound source to be input with the AUX IN connector, through the SR-100. Broadcasting mixed with a MIC sound source is output. Caution : Please connect an expansion keypad (SR-10KR) to the SR-100 in the power-off status. IPC SYSTEM...
  • Page 29: Block Diagrams

    IN TER-M P.A CO N VERGEN CE SYSTEM Block Diagram (SR-100) Block Diagram (SR-100) IPC SYSTEM...
  • Page 30: Specifications

    Frequency Response 300Hz~10kHz 300Hz~15kHz Communication method RS-485 O perating Temperature -10°C ~ +40°C Power Source DC 12V Power Consumption W eight (SET) 1.1kg/ 2.4lb Dimensions (SET) 456(W )x200(H)x65(D)mm/ 18(W )x7.9(H)x2.6(D)in * Specifications and design subject to change without notice. IPC SYSTEM...
  • Page 31: M Ethod To Assemble A Side Pad

    N o. direction. 3. After holding N o. down, assemble the side pad by pressing N o. until “ Tickle” sounds. 4. Fix the bottom with 3 screws to complete assembly. IPC SYSTEM...
  • Page 32: Cautions For Installation Of System

    A C cords of the PD-9359A , after completing unit test where product installation site is a newly constructed environment. Connect power and contact signal for use only when testing before environment will be stabilized. IPC SYSTEM...
  • Page 33: Configuration Of Unit And M Ethod To Install

    1) Connect both mouse and keyboard to the back side of the SM-100 unit 2) Connect RGB cable 3) Connect cables to the Data O ut port of SI-100 and the Data In port of SM-100. 4) Connect a DC 12V adaptor the back side of the SM-100 unit. IPC SYSTEM...
  • Page 34 - 5 Pin : Check whether a chime is used (In use: H) Caution : For supplying power to a DC 12V adapter. - W hen expanding a keyboard using a SR-100KP. - W hen distance between SI-100 and SR-100 is more than 50m. IPC SYSTEM...
  • Page 35 W hen connecting a speaker, check types and features of a speaker to use and then connect the speaker to the back panel and the speaker terminal after separating power cords from the socket by selecting and using appropriate terminals, according to the connection method. IPC SYSTEM...
  • Page 36: Example Of High Impedance Installation

    INTER-M P.A CONVERGENCE SYSTEM Example of high impedance installation Example of high impedance installation 1. WHEN CONNECTING BY USING A SPEAKER OF 50W 2. WHEN CONNECTING IN PARALLEL BY USING A SPEAKER OF 4W Caution : Be sure that the total impedance of a speaker terminal must not be lower than the specified 167 /100V(81.7...
  • Page 37: W Iring Method Of Si-100 And Source Device

    - O peration mode if turning to the right : SI-100 Setup as setup program appears on the screen of SM-100 if the switch is adjusted to the right. 5. EXTERN AL SERIAL CON TROL TERM IN AL Control can be done by moving our CD/ TUN ER unit to RS-232C communication. IPC SYSTEM...
  • Page 38: M Anufacturing Of Cable

    Caution : [For manufacturing of protection connector] 1. Connector between SI-100 and SP-100: Assemble both ends of UTP cable using protection connectors. 2. Connector between SI-100 and SR-100: A ssemble only either side of UTP cable using protection connectors. IPC SYSTEM...
  • Page 39: Application

    IN TER-M P.A CO N VERGEN CE SYSTEM Application Application SM-100 Adapter DC 12V PC-9335AD CD-610/CD-6000 TU-610/TU-6000 SI-100 SPEAKER SP-100 SPEAKER SP-100 PD-9359 IPC SYSTEM...
  • Page 40: To Setup Setup Program

    INTER-M P.A CONVERGENCE SYSTEM To setup SETUP PROGRAM To setup SETUP PROGRAM Setup Program performs automatic allocation of SP-100 ID, input unit setup, Emergency contact setup, SR- 100 Key setup, and setup and transmission of volume and EQ setup to SP-100. Setup process consists of 6 total steps.
  • Page 41 - Designate volume of SP-100 and initial value of EQ . - Setup values are applied to all the SP-100 in the same manner. - Data are transmitted to SP-100 in the Step-6 Download. 4) SP-100 unit list field - Able to check setup contents of SP-100. IPC SYSTEM...
  • Page 42 - If setup is done as in the second figure and EM broadcasts to the output channel CH.2 or CH.3 of SP- 100, then the contact of O UT 1 is O N . - Similarly if SR-100 broadcasts to the output channel CH.4 or CH.5 of SP-100, then the contact of O UT 2 is O N . IPC SYSTEM...
  • Page 43 - It is possible to setup label of 6 output channels of SP-100. Check the channel connected to a speaker after selecting the SP-100 to setup from the SP-100 List. - After the label input field is activated, pressing the [Apply] button enables to add information of the relevant channel to the list. IPC SYSTEM...
  • Page 44 Caution : It is impossible to use DIGI-Link with our PC-9335AD unit. 5) Selection of serial control port: Selects the connected place of the back Serial Control ports. 6) Apply: If inputs are completed, apply by pressing the Apply button. IPC SYSTEM...
  • Page 45 - Select All: Selects all zones in the list. - Release All: Release all area selections in the list. 4) Apply If selection of the zone, which is belonged to the selected group, is completed, apply by pressing the Apply button. IPC SYSTEM...
  • Page 46 - If selection of the zone is completed, apply by pressing the [Apply] button. 3) Selection of sound source - Select the sound source to be broadcast when the emergency contact is input. - Possible for the user to directly add the desiring sound source. IPC SYSTEM...
  • Page 47 - Possible to adjust volume of the emergency MIC installed in the front side of SM-100. 5) Adjustment of EMERGEN CY Message Volume - Possible to adjust a broadcasting volume of the emergency contact sound source selected in 3) IPC SYSTEM...
  • Page 48 Caution : Please setup zones for only SR-100 to actually use. O peration speed of other SR-100 may drop if not connecting the relevant SR-100 after selecting the zone of SR-100. For the SR-100 not be used, initialize all zones by pressing the N o.6 button. IPC SYSTEM...
  • Page 49 Pressing a button enables to store or call setup data to [Step 1 through 5]. N ew contents is added. Contents already stored is selectively deleted. N ame of contents already stored is changed. Store data currently setup in the selected contents. Call data stored in the selected contents. IPC SYSTEM...
  • Page 50 - If calling is completed, modify or store. 8. Convert to operation screen - Convert the screen to ‘SI-100 Server’ as O peration Program if setting the [Mode Select] switch on the rear side of SI-100 to the left after completing and storing all setup. IPC SYSTEM...
  • Page 51: Setup To Sm -100 Touch Screen Focus

    1. Press a window key of the keyboard. 2. Double-click the icon at the right button if work display line appears at the bottom. 3. Select ‘Tool’tap on the upper part if setup program is executed. 4. Press the ‘4-point coordinate setup’ button. IPC SYSTEM...
  • Page 52 IN TER-M P.A CO N VERGEN CE SYSTEM 5. Keep to hold flickering ‘X’ character at the left bottom of the screen until flickering will stop. 6. Repeat ‘X’character moving anti-clockwise as in item 5. 7. Press to ‘O K’ button to exit after completion. IPC SYSTEM...
  • Page 53: Checkpoints Before Using System

    7) EMERGEN CY broadcasting test: Perform contact test after checking Macro setup at the Setup Program at the rear side of the SI-100 unit. Reference : For descriptions required for operation of the SI-100 Server O peration Program, see the [IPC SYSTEM O P Manual]. IPC SYSTEM...
  • Page 54: Service

    To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
  • Page 55 ? @ @ @ @ @ @ @ @ ? ? @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world.