4.3.5
Device orientation
Bypass pipe installation
①
Vent
②
Align front or back of device with
vents
Horn antenna version shown as example
1)
4.4
Installation instructions
Pressure applications
Danger to personnel, system and environment can result from improper installation.
• Improper installation may result in loss of process pressure.
Improper installation
Danger to personnel, system and environment can result from improper installation.
• Installation shall only be performed by qualified personnel and in accordance with local
SITRANS LR250 with mA/HART
Operating Instructions, 10/2019, A5E32220602-AG
1)
WARNING
WARNING
governing regulations.
Stillpipe installation
①
Align front or back of device with stillpipe slots
②
Slots
Installing/mounting
4.4 Installation instructions
1)
33