Siemens 7ML5431 Operating Instructions Manual page 132

Radar transmitters with ma/hart
Table of Contents

Advertisement

Parameter reference
TVT Setup (2.8.7.)
Note
Default settings in the parameter tables are indicated with an asterisk (*) unless explicitly
stated.
Auto False Echo Suppression (2.8.7.1.)
Used together with Auto False Echo Suppression Range (2.8.7.2.) to screen out false
echoes in a vessel with known obstructions. A 'learned TVT' (time varying threshold)
replaces the default TVT over a specified range. See Auto False Echo Suppression
(Page 238) for a more detailed explanation.
Note
• Make sure material level is below all known obstructions when Auto False Echo
Suppression is used to learn the echo profile. (An empty or almost empty vessel is
recommended.)
• Note the distance to material level when Auto False Echo learns the environment. Set
Auto False Echo Suppression Range to a shorter distance to avoid the material echo
being screened out.
• Set Auto False Echo Suppression and Auto False Echo Suppression Range during
startup, if possible.
• If the vessel contains an agitator it should be running.
• Before adjusting these parameters, rotate the instrument for best signal (lower false-echo
amplitude).
132