Pro‐OX 2510‐SXT Iron Filter with Chlorine Side Tank Installa on & Startup Guide
A aching Tubing to the Potassium Permanganate Solu on Tank
& Brine Valve
1. Begin by sliding the brass brine injector nut on to the tubing by pu ng the tubing through the non‐
threaded side of the nut. Next, slide the white compression ring on to the tubing, with the wider side
going on first. Slide this in to the brine injector nut and place the tubing into the brine valve. Finally,
push the nut, which now has the compression ring inside of it, on to the threading of the brine valve and
rotate the nut clockwise, screwing it into the brine valve. Tighten it down to finger ghtness. The tubing
should be firmly a ached and not slide out if pulled upon.
2. To connect the brine line to the solu on tank, slide the plas c solu on tank nut on the brine tubing
through the non‐threaded side of the nut. Next, slide the black (or clear) compression ring with the nar‐
rower side going on first. Then, slide the taller, white compression ring onto the tubing with the wider
diameter going on first. The two compression fi ngs should lay flush against each other on the tubing.
Slide them into the solu on tank nut and place the tubing into the tank valve. Push the solu on tank nut
with the compression rings inside onto the threading of the tank valve and rotate the nut clockwise,
screwing it onto the tank valve. Tighten it down to finger ghtness. The tubing should be firmly a ached
and not slide out if pulled upon.
Page 11
Fig. 8—Brass Brine Injector Nut with White Compression Ring
www.cleanwaterstore.com
Rev 032114