Summary of Contents for Clean Water Systems Fleck 2510-XST
Page 1
Clean Water Made Easy www.cleanwaterstore.com Fleck 2510-XST Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing neutral pH water for many years.
Fig 3 ................................7 Fig 4: ................................7 Assembly and Installation Instructions ....................... 8 Troubleshooting the Fleck 2510-XST Sediment Filter ..................12 Low Water Pressure: ............................ 12 Does NOT remove sediment: ........................12 What to Do If Your Filter Tank Does Not Sit Level on the Floor: ..............12 Page 2 www.cleanwaterstore.com...
1.5 cubic foot of Chemsorb media Sediment Filter 2.0 cubic foot size Quantity 1 Fleck 2510-XST Backwash control Valve with Bypass Assembly and Pipe connector kit (1” or ¾”) Quantity 1 12” x 52” filter tank with distributor tube Blue media funnel for adding the Chemsorb media 2.0 cubic foot of Chemsorb media...
1. See typical installation (see Fig 2). The Sediment Filter is installed after the pressure tank. 2. Make sure to follow to connect the in pipe to the Fleck 2510-XST inlet and the outlet to the outlet (see Fig 2). As you face the Fleck 2510-XST control from the front, the water enters on the right and exits on the left.
Fleck 2510-XST Sediment Installation & Startup Guide plumbing codes require an air-gap connection, so that if your sewer or septic tank backs up, it cannot cross connect with the drain tubing. How Your Sediment Filter Works See Fig 1. In your Sediment Filter the water enters the top of the tank and flows down through the media and up the distributor tube.
Fleck 2510-XST Sediment Installation & Startup Guide Fig 3 : Fleck 2510-XST from the rear showing the inlet and outlet end-connector fittings 1” or 1-1/4” NPT in Noryl plastic. Brass end-connectors are also available for connecting to copper tubing. Drain Line Brine Line for Softening Systems—...
Assembly and Installation Instructions 1. Unscrew by hand the entire Fleck 2510-XST control valve from top of tank if it was shipped screwed on. Place distributor tube in tank if not already inside tank. If not already done, make sure blue cap is on top of distributor tube, or wrap the top of distributor tube with electrical or duct tape.
Page 9
Fleck 2510-XST Sediment Installation & Startup Guide 8. Note that the Fleck 2510-XST is usually shipped in the bypass position. You can easily tell if it is in bypass when the knobs are perpendicular to flow. When in service position, knobs are parallel to water flow (note above).
Page 10
Inlet Side of the bypass valve. Second slowly open the Outlet Side of the bypass until it is in the full service position. The Fleck 2510-XST bypass valve knobs are a little stiff, so you can use a screw driver placed in the holes to turn the knobs.
Page 11
This is the same procedure that needs to be done each time you add Sediment media in the future, that is, the Sediment media must be thoroughly backwashed and rinsed. 23. Refer to your Fleck 2510-XST service manual for more information about how your control valve is programmed if desired. Page 11 www.cleanwaterstore.com...
Sediment Filter. You can verify the backwash flow rate by running the drain line into a bucket and timing it when the Fleck 2510-XST is in Cycle 1 or backwash. A 1.0 or 1.5 cubic foot system should have 7 gallons per minute and a 2.5 cubic foot system should have 10 gallons per minute of backwash at a...
Page 13
Fleck 2510-XST Sediment Installation & Startup Guide 2) From the Service Mode, initiate a manual regeneration, by pressing and holding the regen button (button on far left). 3) The valve will advance to the BW (backwash) position, and start counting down. Press the Regen button again, and wait for the valve to advance and stop at the Rapid Rinse (RR) position.
Need help?
Do you have a question about the Fleck 2510-XST and is the answer not in the manual?
Questions and answers