4.2
Models available
Designation
DB9 LSM C13 TC FB FS1 A0 T150
DUAL IGNITION
4.3
Countries of destination - Burner categories
Gas category
I
- I
- I
(43,46 ÷ 45,3 MJ/m
2L
2E
2
4.4
Technical data
Model
Output
(1)
Fuels
Gas pressure at max. output
Gas: G20/G25
Operation
Modulation/maximum output ratio
Nozzles
Combustion air temperature
Ignition
Weight
Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Pressure at the socket (Fig. 8) with zero pressure in the combustion chamber and at maximum burner output.
(2)
4.5
Electrical data
Model
Electrical supply
Ignition transformer (gas side)
Ignition transformer (oil side)
Absorbed electrical power
Protection level
20135492
Technical description of the burner
I
2H
I
2ELL
3
(0°C))
I
2Er
I
2E(R)B
I
2E
kW
min - max
kg/h
-
(2)
mbar
No.
°C max
kg
V1 - V2
I1 - I2
V1 - V2
I1 - I2
Gas
kW max
Gas oil
kW max
Voltage
230 V / 50-60 Hz
SE - FI - AT - GR - DK - ES - GB - IT - IE - PT - IS - CH - NO
–
Natural gas: G20 - NCV 10 kWh/Nm
–
Natural gas: G25 - NCV 8.6 kWh/Nm
–
Light oil, max. viscosity at 20 °C: 6 mm
–
FS1 Intermittent (min. 1 stop every 24 hours)
–
Modulating
Electrogas type (pilot burner with natural gas - gas side)
Direct ignition with electrodes (oil side)
DB9 LSM C13 - DB12 LSM C13
8
GB
Code
20135016
Destination country
DE
NL
FR
BE
LU - PL
DB9 LSM C13
1500/5500 ÷ 9500
127/460 ÷ 800
3
3
2
/s (1.5°E - 6 cSt)
67.8/101.1
Natural gas 1 : 5
Light oil 1 : 4
1
150
340
230V - 50Hz
230 V - 1 x 8 kV
1.4 A - 30 mA
230 V - 2 x 5 kV
1.9 A - 35 mA
0,5
0,6
IP 54
Tab. A
Tab. B
Tab. C
Tab. D