Sign In
Upload
Manuals
Brands
Riello Manuals
Indoor Fireplace
RS 810/M BLU
Riello RS 810/M BLU Manuals
Manuals and User Guides for Riello RS 810/M BLU. We have
2
Riello RS 810/M BLU manuals available for free PDF download: Modulating Operation, Installation, Use And Maintenance Instructions
Riello RS 810/M BLU Modulating Operation (52 pages)
Forced draught gas burner
Brand:
Riello
| Category:
Indoor Fireplace
| Size: 6.18 MB
Table of Contents
Table of Contents
3
Declarations
5
Information and General Warnings
6
Information about the Instruction Manual
6
Introduction
6
General Dangers
6
Other Symbols
6
Delivery of the System and the Instruction Manual
7
Guarantee and Responsibility
7
Safety and Prevention
8
Introduction
8
Personnel Training
8
Technical Description of the Burner
9
Burner Designation
9
Models Available
9
Burner Categories - Countries of Destination
10
Technical Data
10
Electrical Data
10
Burner Equipment
11
Maximum Dimensions
11
Firing Rates
12
Test Boiler
12
Burner Description
13
Electrical Panel Description
14
4.12 RFGO-A22 Control Box
15
4.13 Servomotor SQM41
16
4.14 Calibration of the Thermal Relay
17
Motor Rotation
17
Installation
18
Notes on Safety for the Installation
18
Handling
18
Preliminary Checks
18
Operating Position
19
Removal of the Locking Screws from the Shutter
19
Preparing the Boiler
19
Boring the Boiler Plate
19
Blast Tube Length
19
Securing the Burner to the Boiler
20
Access to Head Internal Part
20
Probe-Electrode Position
20
Combustion Head Adjustment
21
Gas Feeding
22
5.11.1 Gas Feeding Line
22
5.11.2 Gas Train
23
5.11.3 Gas Train Installation
23
5.11.4 Gas Pressure
23
Electrical Wiring
24
Supply Cables and External Connections Passage
24
Start-Up, Calibration and Operation of the Burner
25
Notes on Safety for the First Start-Up
25
Adjustments Prior to Ignition
25
Burner Start-Up
25
Burner Ignition
26
Servomotor Adjustment
26
Air / Fuel Adjustment
26
Burner Adjustment
27
Output Upon Ignition
27
Maximum Output
27
Minimum Output
28
Intermediate Outputs
28
Pressure Switch Adjustment
29
Air Pressure Switch - Check CO
29
Maximum Gas Pressure Switch
29
Minimum Gas Pressure Switch
29
Operation Sequence of the Burner
30
Burner Start-Up
30
Operation
30
Ignition Failure
30
Burner Flame Goes out During Operation
30
Maintenance
31
Notes on Safety for the Maintenance
31
Maintenance Programme
31
Maintenance Frequency
31
Safety Test - with Gas Feeding Closed
31
Checking and Cleaning
31
Safety Components
32
Opening the Burner
32
Closing the Burner
32
LED Indicator and Special Function
33
Description of LED Lamps
33
Check Mode Function
33
Flame Control Lock-Out or Emergency Stop Condition
33
LED Lamps: Burner Operating Status
34
Problems - Causes - Remedies Signalled by LED Indicators
35
A Appendix - Accessories
40
B Appendix - Electrical Panel Layout
41
Advertisement
Riello RS 810/M BLU Installation, Use And Maintenance Instructions (52 pages)
Forced draught gas burner
Brand:
Riello
| Category:
Burner
| Size: 7.23 MB
Table of Contents
Table of Contents
3
Declarations
5
Information and General Warnings
6
Information about the Instruction Manual
6
Introduction
6
General Dangers
6
Other Symbols
6
Delivery of the System and the Instruction Manual
7
Guarantee and Responsibility
7
Safety and Prevention
8
Introduction
8
Personnel Training
8
Technical Description of the Burner
9
Burner Designation
9
Models Available
9
Burner Categories - Countries of Destination
10
Technical Data
10
Electrical Data
10
Maximum Dimensions
11
Burner Equipment
11
Firing Rates
12
Test Boiler
12
Burner Description
13
Electrical Panel Description
14
4.12 Flame Control RMG88
15
4.13 Servomotor SQM41
16
4.14 Calibration of the Thermal Relay
16
Installation
17
Notes on Safety for the Installation
17
Handling
17
Preliminary Checks
17
Operating Position
18
Removal of the Locking Screws from the Shutter
18
Preparing the Boiler
18
Boring the Boiler Plate
18
Blast Tube Length
18
Securing the Burner to the Boiler
19
Access to Head Internal Part
19
Probe-Electrode Position
19
Combustion Head Adjustment
20
Gas Feeding
21
5.11.1 Gas Feeding Line (Example) - Please Refer to the Gas Train Documentation for more Information
21
5.11.2 Gas Train
22
5.11.3 Gas Train Installation
22
5.11.4 Gas Pressure
22
Electrical Wiring
23
Supply Cables and External Connections Passage
23
Start-Up, Calibration and Operation of the Burner
24
Notes on Safety for the First Start-Up
24
Adjustments Prior to Ignition
24
Burner Start-Up
24
Burner Ignition
25
Servomotor Adjustment
25
Air / Fuel Adjustment
25
Burner Adjustment
26
Output Upon Ignition
26
Maximum Output
26
Minimum Output
27
Intermediate Outputs
27
Pressure Switch Adjustment
28
Air Pressure Switch - Check CO
28
Maximum Gas Pressure Switch
28
Minimum Gas Pressure Switch
28
Operation Sequence of the Burner
29
Burner Start-Up
29
Operation
29
Ignition Failure
29
Burner Flame Goes out During Operation
29
Burner Start-Up Cycle Diagnostics
30
Resetting of Flame Control and Diagnostics Use
30
Flame Control Reset
30
Visual Diagnostics
30
Software Diagnostics
30
Normal Operation / Flame Detection Time
31
Maintenance
32
Notes on Safety for the Maintenance
32
Maintenance Programme
32
Maintenance Frequency
32
Safety Test - with Gas Feeding Closed
32
Checking and Cleaning
32
Safety Components
33
Opening the Burner
33
Closing the Burner
33
Faults - Probable Causes - Solutions
34
Appendix - Accessories
36
B Appendix - Electrical Panel Layout
38
Advertisement
Related Products
Riello RS 810/EV O2 BLU
Riello RS 130/M
Riello RS 610/EV BLU FS2
Riello RS 28/M
Riello RS 250/M MZ
Riello RS 200/E LN
Riello RS 280
Riello RS 610/EV FGR
Riello RS 68/E FGR
Riello RS 810/E FGR
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Water Heater
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL