A 4.4.29 Limit Values

ERRORLIMIT1 <Lower limit value><Upper limit value>
If a measured value or calculated value is to be monitored using ERROROUT1, the limits
can be set here.
The minimum and maximum measured value is processed with four decimal places.
ERRORLIMIT2 <Lower limit value><Upper limit value>
If a measured value or calculated value is to be monitored using ERROROUT2, the limits
can be set here.
The minimum and maximum measured value is processed with four decimal places.

A 4.4.30 Data Selection

ANALOGOUT1 SENSOR1VALUE|SENSOR1INTENSITY|SENSOR1SHUTTER|SENSOR1REFLEC-
TIVITY|SENSOR2VALUE|SENSOR2INTENSITY|SENSOR2SHUTTER|SENSOR2REFLECTIVI-
TY|C-BOXVALUE|FIXED [Value]
Selection of the signal to be output via the analog output1.
For FIXED, the voltage/current value is indicated with four decimal places.
ANALOGOUT2 SENSOR1VALUE|SENSOR1INTENSITY|SENSOR1SHUTTER|SENSOR1REFLEC-
TIVITY|SENSOR2VALUE|SENSOR2INTENSITY|SENSOR2SHUTTER|SENSOR2REFLECTIVI-
TY|C-BOXVALUE|FIXED [Value]
Selection of the signal to be output via the analog output2.
For FIXED, the voltage/current value is indicated with four decimal places.

A 4.4.31 Output Area

ANALOGRANGE1 NONE|0-5V|0-10V|-5-5V|-10-10V|4-20mA
- NONE: No analog output (inactive)
- 0 - 5 V: The analog output1 outputs a voltage of 0 to 5 volts.
- 0 - 10 V: The analog output1 outputs a voltage of 0 to 10 volts.
- -5 - 5 V: The analog output1 outputs a voltage of -5 to 5 volts.
- -10 - 10 V: The analog output1 outputs a voltage of -10 to 10 volts.
- 4 - 20 mA: The analog output1 outputs a current of 4 to 20 mA.
ANALOGRANGE2 NONE|0-5V|0-10V|-5-5V|-10-10V|4-20mA
- NONE: No analog output (inactive)
- 0 - 5 V: The analog output2 outputs a voltage of 0 to 5 volts.
- 0 - 10 V: The analog output2 outputs a voltage of 0 to 10 volts.
- -5 - 5 V: The analog output2 outputs a voltage of -5 to 5 volts.
- -10 - 10 V: The analog output2 outputs a voltage of -10 to 10 volts.
- 4 - 20 mA: The analog output2 outputs a current of 4 to 20 mA.

A 4.4.32 Two-point Scaling

ANALOGSCALE1 STANDARD|(TWOPOINT <Minimum measured value> <Maximum mea-
sured value>)
Setting the scaling of analog output1.
The standard scaling is for distances -MR/2 to MR/2, for thickness measurement 0 to 2 MR (MR =
measuring range), for intensity 0 to 100 %.
If the minimum and maximum measured value is '0', standard scaling is used.
The minimum and maximum measured value must be indicated in millimeters (distance/thickness)
or % (intensity).
The available output area of the analog output is then spread between the minimum and maximum
values. The minimum and maximum measured value must be between -1024.0 and 1024.0 mm
with four decimal places.
The minimum and maximum measured value is processed with four decimal places.
ANALOGSCALE2 STANDARD|(TWOPOINT <Minimum measured value> <Maximum mea-
sured value>)