Appendix | ASCII Communication with the Sensor
thicknessSENSOR
A 4.4.25 Data Selection for Ethernet
OUT_ETH NONE|([SENSOR1VALUE][SENSOR1INTENSITY][SENSOR1SHUTTER][SENSOR-
1REFLECTIVITY][SENSOR2VALUE][SENSOR2INTENSITY][SENSOR2SHUTTER][SENSOR-
2REFLECTIVITY][C-BOXVALUE][C-BOXCOUNTER][C-BOXTIMESTAMP][C-BOXDIGITAL])
Setting which values are to be output via Ethernet.
- NONE: No output of a distance
- SENSOR1VALUE: Measured value of Sensor 1
- SENSOR1INTENSITY: Intensity of Sensor 1
- SENSOR1SHUTTER: Shutter speed of Sensor 1
- SENSOR1REFLECTIVITY: Reflectivity of Sensor 1
- SENSOR2VALUE: Measured value of Sensor 2
- SENSOR2INTENSITY: Intensity of Sensor 2
- SENSOR2SHUTTER: Shutter speed of Sensor 2
- SENSOR2REFLECTIVITY: Reflectivity of Sensor 2
- C-BOXVALUE: Calculated value of thicknessSENSOR
- C-BOXCOUNTER: Counter value of thicknessSENSOR
- C-BOXTIMESTAMP: Timestamp of thicknessSENSOR
- C-BOXDIGITAL: Digital inputs/outputs of thicknessSENSOR
A 4.4.26 Function Selection Multi-function Input
MFIFUNC NONE|MASTER|SENSOR1|SENSOR2|SENSOR12 LLL|HLL
Function of the multi-function input, either mastering or output to one or both multi-func-
tion outputs (sensor).
- NONE -> No function
- MASTER -> C-Box mastering
- SENSOR1 -> Multi-function output for sensor 1
- SENSOR2 -> Multi-function output for sensor 2
- SENSOR12 -> Multi-function output for sensor 1 and 2
- LLL -> Low Level Logic input
- HLL -> High Level Logic input
A 4.4.27 Activate Error Output, Switching Output 1
ERROROUT1 SENSOR1ERROROUT1|SENSOR1ERROROUT2|SENSOR2ERROROUT1|SENSOR-
2ERROROUT2|SENSOR1VALUE|SENSOR1INTENSITY|SENSOR1SHUTTER|SENSOR1RE-
FLECTIVITY|SENSOR2VALUE|SENSOR2INTENSITY|SENSOR2SHUTTER|SENSOR2REFLEC-
TIVITY|C-BOXVALUE|LOW|HIGH
Select the signal source for the switching output 1 (to the periphery).
The first four switch only one error output of the sensors.
The next nine monitor values from the
The last two switch the output to a level by command.
A 4.4.28 Activate Error Output, Switching Output 2
ERROROUT2 SENSOR1ERROROUT1|SENSOR1ERROROUT2|SENSOR2ERROROUT1|SENSOR-
2ERROROUT2|SENSOR1VALUE|SENSOR1INTENSITY|SENSOR1SHUTTER|SENSOR1RE-
FLECTIVITY|SENSOR2VALUE|SENSOR2INTENSITY|SENSOR2SHUTTER|SENSOR2REFLEC-
TIVITY|C-BOXVALUE|LOW|HIGH
Select the signal source for the switching output 2 (to the periphery).
The first four switch only one error output of the sensors.
The next nine monitor values from the sensors or the thicknessSENSOR.
The last two switch the output to a level by command.
thicknessSENSOR.
Page 63
Need help?
Do you have a question about the thicknessSENSOR 10/200 and is the answer not in the manual?
Questions and answers