INTRODUCTION

This manual provides installation and operation instructions for the Badger Meter Data Industrial

Product Unpacking and Inspection

Upon receipt of the product, perform the following unpacking and inspection procedures:
NOTE: If damage to the shipping container is evident upon receipt, request the carrier to be present when the
product is unpacked.
Carefully open the shipping package and follow any instructions that may be marked on the exterior. Remove all cushioning
material surrounding the product and carefully lift the product from the package. Retain the package and all packing material
for possible use in reshipment or storage.
Visually inspect the product and applicable accessories for any physical damage such as scratches, loose or broken parts, or
any other sign of damage that may have occurred during shipment.
NOTE: If damage is found, request an inspection by the carrier's agent within 48 hours of delivery and file a claim
with the carrier. A claim for equipment damage in transit is the sole responsibility of the purchaser.

Product Description

The Badger Meter Data Industrial Series 3050 Btu Monitor is an economical, full-featured compact unit designed for
sub-metering applications.
The two line x 16-character alphanumeric displays any combination of Energy Rate, Energy Total, Flow Rate or Flow Total.
Both preprogrammed and user defined units of measure can be configured by the user.
The Series 3050 accepts pulse or linear analog input signals. Like all Data Industrial flow monitors, the Series 3050 may be
field calibrated by the user. For Data Industrial sensors,"K" and "offset" numbers are entered, while other pulse or frequency
output sensors may use a "K" factor only. Analog inputs are fully programmable for slope and intercept.
The unit requires two temperature units and can accept 10 K ohm thermistors, 100Ώ three wire RTDs or user defined custom
thermistors or RTDs.
The panel meter has a NEMA 4X rated front panel and conforms to DIN Standard dimensions, 96 mm X 96 mm, for meter sizes
and panel cutouts. Optional NEMA 4 wall mount is also available.
6-11
Installation & Operation Manual
®
Series 3050 Btu Monitor.