Technical Data

The following table lists input values for the appliance.
Burner
Oriice Size
Main
1.07mm (#58)
Side
0.82mm
Ceriied Gases / Pressures - Check raing plate to ensure that it corresponds with following list.
Gas Category
Gases / Pressures
Countries
Do not tamper with or modify regulator. Use only regulator which supply the pressure listed in the table
above. A regulator of 28 – 30 mbar must be used for butane or a 37 mbar regulator for propane. The grill is
equipped with an internal regulator. This internal regulator has an outlet pressure of 24.5 mbar for propane/
butane and must not be modiied or adjusted. For replacement, use only the
manufacturer.
This unit includes an internal regulator which stabilizes the gas pressure and improves grill performance.
This regulator cannot be adjusted. There is a pressure tap located on the side of the regulator. It can
be used by a qualiied service person when servicing the grill to determine if the regulator is funcioning
properly. The screw within the pressure tap must always be kept ight, except when performing a pressure
test on the regulator (qualiied service personnel only).
Leak Tesing Instrucions
WARNING!
A leak test must be performed annually and each ime a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING!
Never use an open lame to check for gas leaks. Be certain no sparks or open lames are in
the area while you check for leaks. Sparks or open lames will result in a ire or explosion, damage to prop-
erty, serious bodily injury, or death.
Leak tesing: This must be done before iniial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of igniion. See Leak Tesing Dia-
gram for areas to check. Turn all burner controls to the of posiion. Turn gas supply valve on.
Brush a half-and-half soluion of liquid soap and water onto all joints and connecions of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ighten the loose joint or have the part replaced with one recommend-
ed by the Napoleon Customer Care department and have the grill inspected by a ceriied gas installer.
If the leak cannot be stopped, immediately shut of the gas supply, disconnect it, and have the grill inspected
by a ceriied gas installer or dealer. Do not use the grill unil the leak has been corrected.
(Gross) Heat Input (Total)
8.0 kw
2.4 kw
3B/P(30)
3+(28-30/37)
3B/P(37)
I
I
I
Butane 30mbar
Butane 28-30mbar
Butane 37mbar
Propane 30mbar
Propane 37mbar
Propane 37mbar
BE, BG, CY, DK,
BE, CH, CY, CZ, ES,
PL
EE, FI, FR, GB,
FR, GB, GR, IE, IT,
HR, HU, IS, IT,
LT, LU, LV, PT, SK, SI
LT, LU, MT, NL,
NO, RO, SE, SI,
SK, TR
Gas Usage (Total)
580 g/hr
174 g/hr
3B/P(50)
I
Butane 50mbar
Propane 50mbar
AT, CH, DE, SK
regulator speciied by the