Technical Data

The following table lists input values for the appliance.
Burner
Main
rear
Side (Infra red)
Side (Flame)
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with the following list.
Gas Category
Orifice Sizes(see above)
Gases / Pressures
Countries
Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table
above. For replacement, use only the regulator specified by the manufacturer.
N415-0567CE-GB-DE Mar 25.20
Orifice Size
(Gross) Heat
Input (Total)
I
II
#61
#65
16.6 kW
#57
#62
#59
#64
0.86mm
#69
I
3B/P(30)
I
Butane 30mbar
Propane 30mbar
BE, BG, CY, DK, EE,
FI, Fr, GB, Hr, HU,
IS, IT, LT, LU, MT,
NL, NO, rO, SE, SI,
SK, Tr
(Gross) Heat
Gas Usage
Input (Total)
525
625
I / II
I / II
20.75 kW
1208 g/hr
5.0 kW
5.0 kW
364 g/hr
4.5 kW
4.5 kW
327 g/hr
3.0 kW
3.0 kW
218 g/hr
I
I
3+(28-30/37)
3B/P(50)
I
II
Butane 28-30mbar
Butane 50mbar
Propane 37mbar
Propane 50mbar
BE, CH, CY, CZ, ES,
Fr, GB, Gr, IE, IT, LT,
aT, CH, DE, SK
LU, LV, PT, SK, SI
7
EN
Gas Usage
(Total)
(Total)
525
625
I / II
I / II
1514 g/hr
364 g/hr
327 g/hr
218 g/hr