Resolving Suspected Ethernet Controller Problems; Troubleshooting By Symptom - Lenovo ThinkSystem SR630 Maintenance Manual

Hide thumbs Also See for ThinkSystem SR630:
Table of Contents

Advertisement

Note: Start with the event log of the application that is managing the server. For more information
about event logs, see "Event logs" on page 227.
Step 2.
Check for short circuits, for example, if a loose screw is causing a short circuit on a circuit board.
Step 3.
Remove the adapters and disconnect the cables and power cords to all internal and external
devices until the server is at the minimum configuration that is required for the server to start. See
"Specifications" on page 2 to determine the minimum configuration for your server.
Step 4.
Reconnect all ac power cords and turn on the server. If the server starts successfully, reseat the
adapters and devices one at a time until the problem is isolated.
If the server does not start from the minimum configuration, replace the components in the minimum
configuration one at a time until the problem is isolated.

Resolving suspected Ethernet controller problems

The method that you use to test the Ethernet controller depends on which operating system you are using.
See the operating-system documentation for information about Ethernet controllers, and see the Ethernet
controller device-driver readme file.
Complete the following steps to attempt to resolve suspected problems with the Ethernet controller.
Step 1.
Make sure that the correct device drivers, which come with the server are installed and that they
are at the latest level.
Step 2.
Make sure that the Ethernet cable is installed correctly.
• The cable must be securely attached at all connections. If the cable is attached but the problem
remains, try a different cable.
• If you set the Ethernet controller to operate at 100 Mbps or 1000 Mbps, you must use Category
5 cabling.
Step 3.
Determine whether a hub is installed in the network environment. If yes, use direct connection from
a server adapter port to a laptop to clarify the network issue. If the network environment is for
unique fiber channel connectors (such as SFP+ and QSFP), use another known good server for
direct connection to clarify the issue first.
Step 4.
Check the Ethernet controller LEDs on the rear panel of the server. These LEDs indicate whether
there is a problem with the connector, cable, or hub.
• The Ethernet link status LED is lit when the Ethernet controller receives a link pulse from the hub.
If the LED is off, there might be a defective connector or cable or a problem with the hub.
• The Ethernet transmit/receive activity LED is lit when the Ethernet controller sends or receives
data over the Ethernet network. If the Ethernet transmit/receive activity is off, make sure that the
hub and network are operating and that the correct device drivers are installed.
Step 5.
Check the LAN activity LED on the rear of the server. The LAN activity LED is lit when data is active
on the Ethernet network. If the LAN activity LED is off, make sure that the hub and network are
operating and that the correct device drivers are installed.
Step 6.
Check for operating-system-specific causes of the problem, and also make sure that the operating
system drivers are installed correctly.
Step 7.
Make sure that the device drivers on the client and server are using the same protocol.
If the Ethernet controller still cannot connect to the network but the hardware appears to be working, the
network administrator must investigate other possible causes of the error.

Troubleshooting by symptom

Use this information to find solutions to problems that have identifiable symptoms.
ThinkSystem SR630 V2 Maintenance Manual
230