Lenovo ThinkSystem SR630 Maintenance Manual page 169

Hide thumbs Also See for ThinkSystem SR630:
Table of Contents

Advertisement

1. Disable security.
OneCli.exe config set IntelOptanePMEM.SecurityOperation "Disable Security"
--bmc USERID:PASSW0RD@10.104.195.86
2. Enter passphrase.
OneCli.exe config set IntelOptanePMEM.SecurityPassphrase "123456"
--bmc USERID:PASSW0RD@10.104.195.86
3. Reboot the system.
– Single PMEM: Choose this option to run security operation on one or more selected PMEM units.
Notes:
• Single PMEM passphrases are not stored in the system, and security of the locked units needs to
be disabled before the units are available for access or secure erase.
• Always make sure to keep records of the slot number of locked PMEMs and corresponding
passphrases. In the case the passphrases are lost or forgotten, the stored data cannot be backed
up or restored, but you can contact Lenovo service for administrative secure erase.
• After three failed unlocking attempts, the corresponding PMEMs enter "exceeded" state with a
system warning message, and the PMEM unit can only be unlocked after the system is rebooted.
To enable passphrase, go to Security ➙ Press to Enable Security.
– Secure Erase
Notes:
– Password is required to perform Secure Erase when security enabled.
– Before executing secure erase, make sure ARS (Address Range Scrub) is done on all PMEMs or on
the specific PMEMs selected. Otherwise, secure erase cannot be started on all PMEMs or the
specific PMEM selected, and the following text message will pop out:
The passphrase is incorrect for single or multiple or all
Intel Optane PMEMs selected, or maybe there is namespace on
the selected PMEMs. Secure erase operation is not done
on all Intel Optane PMEMs selected.
Secure erase cleanses all the data that is stored in the PMEM unit, including encrypted data. This data
deletion method is recommended before returning or disposing a malfunctioning unit, or changing
PMEM mode. To perform secure erase, go to Security ➙ Press to Secure Erase.
Alternatively, perform platform level secure erase with the following command in OneCLI:
OneCli.exe config set IntelOptanePMEM.SecurityOperation "Secure Erase Without Passphrase"
--bmc USERID:PASSW0RD@10.104.195.86
• PMEM Configuration
PMEM contains spared internal cells to stand in for the failed ones. When the spared cells are exhausted
to 0%, there will be an error message, and it is advised to back up data, collect service log, and contact
Lenovo support.
There will also be a warning message when the percentage reaches 1% and a selectable percentage
(10% by default). When this message appears, it is advised to back up data and run PMEM diagnostics
(see
https://sysmgt.lenovofiles.com/help/topic/LXPMv3/diagnostics.html
percentage that the warning message requires, go to Intel Optane PMEMs ➙ PMEM Configuration, and
input the percentage.
Alternatively, change the selectable percentage with the following command in OneCLI:
OneCli.exe config set IntelOptanePMEM.PercentageRemainingThresholds 20
). To adjust the selectable
.
Chapter 4
Hardware replacement procedures
159

Advertisement

Table of Contents
loading

Table of Contents