Communication Warning/Fault Codes; Drive Warning/Fault Codes - Delta CMC-EC01 Operation Manual

Ethercat
Hide thumbs Also See for CMC-EC01:
Table of Contents

Advertisement

EtherCAT Option Card CMC-EC01

6. Communication Warning/Fault Codes

6.1

Drive Warning/Fault Codes

Warning/Fault
ID No.
Code
81
ECto_WARN
89
ECCb_WARN
111
SYCE_WARN
161
SYCE_ERR
Warning/Fault
Name
Communication time-out
EtherCAT
warning between the
communication
communication card and the
time-out
host computer
Communication
Communication card
card detached
detachment warning
Command source of the drive is
NOT the communication card.
This warning is displayed when
Sync error
synchronization signal (packet)
is lost after synchronization
mode is set.
Command source of the drive is
the communication card.
This fault is displayed when
Sync error
synchronization signal (packet)
is lost after synchronization
mode is set.
Description
Corrective Actions
Check if communication
system is properly connected.
Check if connection to the host
computer is normal.
Reinstall the communication
card.
Replace the communication
card or drive.
The host computer
reconfigures the drive.
The host computer
reconfigures the drive.
CMC-EC01 Operation Manual 39

Advertisement

Table of Contents
loading

Table of Contents