Attaching the Left 'Up' Line
1. Locate the left 'Up' line that goes from the left cylinder to the stack
valve.
2. Disconnect the left 'Up' line from the stack valve.
3. Attach the supplied -12 JIC tee fitting to the port on the stack valve.
4. Attach the original left 'Up' hose to the Tee fitting.
5. Attach the 90 degree end of the hose (P/N 214-1000-298) to the other
side of the tee fitting.
6. Run the hose to the LC port on the Autoboom valve.