Technical Characteristics - Parker Compax3F Fluid Installation Manual

Hydraulics controller
Table of Contents

Advertisement

Technical Characteristics

4. Technical Characteristics
22
Voltage supply 24VDC
Controller type
Voltage range
Mains module
Fuse
Current drain of the device
Total current drain
Ripple
Requirement according to safe extra
low voltage (SELV)
Size / weight
Controller type
Dimensions: HxWxD [mm]
Weight [kg]
Housing / protection class
Inputs And Outputs
Controller type
8 control inputs
4 control outputs
4 analog current inputs
2 analog voltage inputs
4 analog outputs
2 analog monitor outputs
COM ports
RS232
RS485 (2 or 4-wire)
Supported valves and feedback systems
Valves
Absolute encoder
192-121100 N8 September 2014
Hydraulics Controller
Compax3 F001 D2
21 - 27VDC
with switch-on current limitation, due to
capacitive load
MTP miniature circuit breaker or "delayed action
fuse", due to capacitive load
0.8A (max. 1.5A)
0.8A + total load of the digital outputs
<1Vss
yes
Compax3 F001 D2
199x80x130
2.0
Enclosed metal housing, insulation according to
EN60529 / IP 20
Compax3 F001 D2
24 VDC / 10 kOhm
Active HIGH / short-circuit proof / 24 V / 100 mA
14 Bit
14 Bit
16 Bits, current or voltage
8 Bit
115200 baud
Word length: 8 bits, 1 start bit, 1 stop bit
Hardware handshake XON, XOFF
9600, 19200, 38400, 57600 or 115200
baud
Word length 7/8 bit, 1 start bit, 1 stop bit
Parity (can be switched off) even/odd
2 or 4-wire
D1*FH series
Analog 0..20mA, 4..20mA, ±10V
Start/Stop - interface
SSI interface
EnDat 2.1-interface
1VSS (max. 400kHz) Interface, 13.5bits /
graduation of the scale
RS422 Encoder (max. 5MHz, (track A or
B) internal resolution quadrature

Advertisement