1. Safety Considerations

Intended Use

The ADView 2 is a clinical-grade, automated blood pressure measurement device with optional temperature
and pulse oximetry modules for spot-check vital sign measurements in physician offices, long-term care
facilities, and low-acuity areas in hospitals. The ADView 2 can be used in combination with a clinical IT
network to transfer and store patient measurement data on an EMR system.  

Indications for Use

The ADView 2 is a non-invasive oscillometric spot-check vital signs device. The ADView 2 is capable of measuring
and displaying brachial systolic and diastolic blood pressure, heart rate, percent oxygenated hemoglobin (SpO
) and
2
body temperature on children 3 years of age to adults. This device is intended for use by a qualified clinician when it
is necessary to take a single or a series of vital signs measurements on a patient. The ADView 2 is only for
measurement, recording and display. It makes no specific diagnoses.
The ADView 2 is intended to be used on adult and pediatric patients using appropriately sized ADC ADView 2 blood
pressure cuffs.

User Responsibility

Your ADView 2 is designed to perform in conformity with the description thereof contained in this operation manual
and accompanying labels and inserts, when assembled, operated, maintained and repaired in accordance with the
instructions provided.
Further, the user of this device bears sole responsibility for any malfunction that results from improper use, faulty
maintenance, improper repair, damage or alteration by anyone other than ADC or authorized service personnel.
Use of ADView 2
Use only ADView 2 blood pressure cuffs supplied by ADC.
Observe the patient carefully during the measurement. Ensure pressure compatibility to all patients. If any
abnormality occurs, either in the unit or the patient, suspend the operation immediately and disconnect the BP cuff,
SpO
sensor and thermometer (if applicable) from the patient.
2
Accuracy of any BP reading or oxygen saturation measurement may be affected by the position of the patient, their
physical condition and use outside of the operating instructions detailed in this guide. The interpretation of BP and
oxygen saturation measurements should only be made by a physician.
Safety and effectiveness when used with pregnant women, children under 3 years of age and neonates have not been
established.
Pulse Oximetry (SpO
)
2
TM
ChipOx SpO
Module: Use only pulse oximeter sensors supplied by ADC or original Nellcor
pulse oximeter sensors
2
®
supplied by Covidien
(except for forehead reflectance sensors).
®
Masimo
SpO
Module: Use only original Masimo pulse oximeter sensors and cables.
2
Check the application site of the SpO
sensor frequently to confirm proper positioning of the sensor and to check the
2
circulation and skin sensitivity of the patient.
93-9005-00 rev 4
ADView 2 User Manual | 6
September 1, 2016