Installation Manual – Hardware Installation
BBU3806 WCDMA Base Band Unit

Figure B-1 Outline of a round communication cable

Figure B-2 Outline of a flat telephone cable

Caution:
When stripping the round communication cable and the flat telephone cable, make
sure that the end of the sheath is neat and vertical to the axial.
Do not damage the shielding layer around a shielded cable when stripping the
cable sheath. After the stripping, fold the shielding layer back by the root of the
cable sheath as shown in Figure B-3.
Cut the core wires neatly, especially for the round communication cable. Spread
the core wires evenly apart and cut them neatly with the cutting tool, as shown in
Figure B-4.
The length of the truncated cable should comply with the requirements shown in
Figure B-4. The core wires of the round communication cable or the flat telephone
core wire is "L" in length.
(1) A folded shielding layer

Figure B-3 Outline of a shielded cable