Table 7-4 Indicators on BBU3806 panel

Indicator
RUN
ALM
ACT
LIU0
LIU1
OPT0
OPT1
OPT2
Color
State
ON
OFF
Green
Flashing slowly
at 0.5 Hz
Flashing fast at
4 Hz
ON
Red
OFF
ON
Green
OFF
ON
Green
Flashing
OFF
ON
Green
Flashing
OFF
ON
Green
Flashing
OFF
ON
Green
Flashing
OFF
ON
Green
Flashing
OFF
Huawei Technologies Proprietary
7-4
Chapter 7 Checking Hardware Installation
Description
There is power input, but a board is faulty.
There is no power input, or the board is
faulty.
The board is working normally under
current configuration.
Software is being loaded to the board or
the board has not been configured.
The board is in the alarming state.
The board is normal.
The board is working normally.
The board is not in use.
No Rx signals at E1_0
Loss of Tx signals at E1_0
Normal transmission at E1_0
No Rx signals at E1_1
Loss of Tx signals at E1_1
Normal transmission at E1_1
No Rx signals at optical interface 0
Loss of Tx signals at optical interface 0
Normal transmission at optical interface 0
No Rx signals at optical interface 1
Loss of Tx signals at optical interface 1
Normal transmission at optical interface 1
No Rx signals at optical interface 2
Loss of Tx signals at optical interface 2
Normal transmission at optical interface 2