Important:
If the user proceeds with a method that requires the DIO to be manually changed in the
SYNC Inputs tab (Method 2 and Method 3), the user must also ensure the DIO settings in
the Output tab to be set to Active Low for BOTH Outputs. A Factory Reset also sets the
Output DIO to Active Low by default.
4.2 Thermocouple Connection
The iS2-THB-DTC can accept up to two thermocouples. Refer to the thermocouple connector
diagram below to properly connect your thermocouple sensor to the iServer 2 unit.
Important:
Currently there is Cold Junction Calibration menu available for B-type thermocouples.
To compensate for the B-type thermocouple wire error, users may configure the Offset
(b) and Gain (m) available in the sensor channel settings menu. Refer to section 6.7.1
Gain and Offset for more information.
Figure 7: SYNC Configuration Smart Probe Output set to Active Low
Figure 8: iServer 2 unit with Thermocouple connectors
9 |