Gas Line Requirements - Travis Industries Fire Garden 40x24 Single Sided Manual

Table of Contents

Advertisement

18

Gas Line Requirements

MASSACHUSETTS INSTALLATIONS - WARNING:
THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH
OF MASSACHUSETTS.
OTHER MASSACHUSETTS CODE REQUIREMENTS:
Flexible connector must not be longer than 36 inches.
Shutoff must be a "T" handle gas cock.
Only direct vent sealed combustion products are approved for bedrooms or bathrooms.
Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.
A carbon monoxide (CO) detector is required in the same room as the appliance.
!
The gas line must be installed in accordance with all local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, International Fuel Gas Code, Natural Gas, and Propane Installation Code, CSA B149.1, or
Propane Storage and Handling Code, B149.2, as applicable. Consult your local gas supplier or propane gas dealer for code
regulations and recommended procedures.
!
The fireplace and gas control module must be disconnected from the gas supply piping during any pressure testing of that
system at test pressures in excess of 1/2 psig. For pressures less than 1/2 psig, isolate the gas supply piping by closing the
manual shut-off valve.
!
Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.
Gas Line Connection
Installation must be performed by a qualified
installer, service agency, or the gas supplier
(In Massachusetts a licensed
plumber/gasfitter).
An accessible manual gas shutoff valve is
required on the gas supply to the fireplace and
must be installed upstream of the fireplace gas
valve. A shut-off valve is included with the
fireplace. Check with the local authority
having jurisdiction for any additional
requirements.
The supply regulator (the regulator that
attaches directly to the residence inlet or the
propane tank) should supply gas at the
required input pressure detailed in the section
"LP Conversion and Turndown Conversion" on
page 5. Contact the local gas supplier if the
regulator is at an improper pressure.
The gas can be stubbed into the area under
the appliance indicated by the shaded boxes
(see diagrams to the right).
The appliance comes with a 34" flex.
Connect the incoming gas line to the flex (the
flex accepts ¾" MPT)
 
© Travis Industries, Inc.
Installation
 
3/20/23 - 1580
(qualified installers only)
40x24 Fireplace
a
39-1/4" (997mm)
b
5-1/2" (140mm)
5-1/2" (140mm)
c
+ Depth of framing
 
64x24 Fireplace
63-1/4" (1607mm)
5-1/2" (140mm)
5-1/2" (140mm)
+ Depth of framing
ODL Fireplaces

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fire garden 40x24 see-throughFire garden 64x24 single sidedFire garden 64x24 see-through949002909490029694900300 ... Show all

Table of Contents