Power Distribution Board; Removing The Power Interposer Board - Dell PowerEdge R660xs Installation And Service Manual

Table of Contents

Advertisement

Figure 126. Installing a power supply unit
Next steps
1. If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the
system's rack documentation at https://www.dell.com/poweredgemanuals.
2. Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION:
When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE:
When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the system to recognize the
PSU and determine its status. The PSU redundancy may not occur until discovery is complete. The PSU status indicator
turns green to indicate that the PSU is functioning properly.
NOTE:
For certain premium configurations with high power consumption, system PSU might stay with 2+0 mode only, 1+1
redundant mode is not available.
NOTE:
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For updating to the latest firmware and changing the configuration, see the
Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals.

Power distribution board

This is a service technician replaceable part only.

Removing the power interposer board

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in
3.
Remove the air
shroud.
4. Remove the
PSU
or
PSU
5. Disconnect the cables that are connected to power interposer board (PIB).
Steps
1. Using a Phillips 2 screwdriver, remove the screws securing the power interposer board to the system.
Safety
instructions.
Before working inside your system
blank.
.
Installing and removing system components
157

Advertisement

Table of Contents
loading

This manual is also suitable for:

E87s

Table of Contents