UL 325 LISTING: Edge sensors and photo eyes must
be tested and labeled as "Recognized Components" or
otherwise certifi ed to UL 325 requirements in order to
be deemed acceptable for use in a gate operator. Study
325
Important Safety Instructions and consider your specifi c
installation to determine where greatest entrapment
risks exist. Locate edge sensors and/or photo sensors
accordingly. Be certain that a suffi cient number of sensors
are used so that pedestrians are protected from entrapment
Nice | HySecurity Recommended Sensors
in both directions of gate travel and all hazard areas are fully
protected. Most HySecurity gate operators require external
Mfg. Part # or
entrapment sensors that utilize Normally Closed (NC) contact
Model
means of monitoring. HySecurity gate operators utilizing the
SmartCNX Controller or the SmartTouch 720/725 Controller
E3K-R10K4-NR-1
require external entrapment sensors that have a 10k Ohm
Photo Eyes
NIR-50-325
(Retro
or 4-wire pulsed monitoring scheme. Refer to UL website at
-reflective)
IRB-RET
www.ul.com
for most up-to-date list of gate operator safety
E-931-S50RRGQ
standards (UL 325). Refer to
list of ASTM F2200 Gate and Fence Standards.
Blue Bus
Photo Eyes
Era Photo Eyes
(Thru-Beam)
OVS-50TNR
IRB-MON
E-960-D90GQ
Sentir Series
Edge
Sensors
CPT210-2U-#-T2
Hy2NC (Converts 10K
Edge Sensor
to NC Monitoring)
Converters
GEM103 (Converts 10K
to Pulsed Monitoring)
Edge
325
iGAZE RE Kit
Wireless
Kits
WEL-200
Multi-Input
Module
The Solution – MIM-62
Nice | HySecurity Recommended Sensors
UL 325 Standard:
• The operator shall monitor for the presence of every device at least once during each open and close cycle (32.1.8)
Mfg. Part # or
• It shall not be possible to make simple modifications in the field by adding, suppressing or changing, either on the operator or
Model
external entrapment protection device(s), to bypass, interfere with, or otherwise defeat the monitoring function. (32.1.10)
• Entrapment zones are now defined for each gate type (4.23, 4.24, 4.29, 4.34)
E3K-R10K4-NR-1
Slide Gates: To enable fully automatic operation, all SLIDE gate operators will require a minimum of TWO monitored external
Photo Eyes
NIR-50-325
entrapment protection sensors (one for each direction) to protect entrapment zones in both the open and close direction of travel.
(Retro
Preferred solution for slide gates: A photo eye for the close direction and a hard-wired edge sensor for the open direction that is mounted
-reflective)
IRB-RET
to the face of the leading post of the fence behind the gate. (Reach through injuries are the most common hazard associated with
E-931-S50RRGQ
automatic sliding gates)
Swing Gates: To enable fully automatic operation, all SWING gate operators will require a minimum of ONE monitored external
entrapment protection sensor to protect entrapment zones in either the open or close direction of travel. However, an additional
monitored sensor is required if there is a risk of entrapment in both directions of gate travel.
Blue Bus
Photo Eyes
Preferred solution for swing gates: A photo eye for the close direction and/or a hard-wired wraparound edge sensor on the leading edge
Era Photo Eyes
(Thru-Beam)
of the gate, which protects for both directions of gate travel.
OVS-50TNR
IRB-MON
E-960-D90GQ
Sentir Series
Edge
Sensors
Recommended External Entrapment
Protection Sensors List
The following sensors have been tested with Nice | HySecurity gate operators by an
independent laboratory and certified to comply with UL 325 7th Edition. Select sensors from
this list for UL compliant gate automation solutions. Contact the sensor manufacturer for
specific recommendations for use.
Brand
Omron
MX000999
EMX
-
EMX
-
Seco-Larm
-
www.astm.org
for a complete
EPMB/A
EPMOB/A
EPLOB/A
Nice |
EPMAB/A
HySecurity
EMBORB/A
Optex
-
EMX
MX3990
Seco-Larm
-
"AS1502-*
ASO Safety
AS1501-*"
Recommended External Entrapment
Miller Edge
-
Protection Sensors List
HySecurity
MX4018
Miller Edge
-
Transmitter
The following sensors have been tested with Nice | HySecurity gate operators by an
Solutions
-
independent laboratory and certified to comply with UL 325 7th Edition. Select sensors from
EMX
-
this list for UL compliant gate automation solutions. Contact the sensor manufacturer for
specific recommendations for use.
Miller Edge
-
Brand
Omron
MX000999
EMX
-
EMX
-
Seco-Larm
-
EPMB/A
EPMOB/A
EPLOB/A
Nice |
EPMAB/A
HySecurity
EMBORB/A
Optex
-
EMX
MX3990
Seco-Larm
-
"AS1502-*
ASO Safety
AS1501-*"
SAFETY REQUIREMENTS
Nice |
Max
Smart
Hysecurity
Range
Touch
Part #
40 ft
45 ft
53 ft
46 ft
45 ft
33 ft
65 ft
90 ft
Nice |
Max
Smart
Hysecurity
Range
Touch
Part #
40 ft
45 ft
53 ft
46 ft
45 ft
33 ft
65 ft
90 ft
Control Boards
Smart
SmartCNX
1050
DC
Control Boards
Smart
SmartCNX
1050
DC
hysecurity.com | 800-321-9947
MX5386 Rev. B ©2023
Mercury
310
Mercury
310
1 of 2
Page
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SlideDriver II and is the answer not in the manual?

Table of Contents

Save PDF