Perc Module; Removing The Rear Mounting Front Perc Module - Dell PowerEdge R7615 Installation And Service Manual

Table of Contents

Advertisement

Figure 97. 24 x 2.5 inch U.2 drives Gen5 Single Width
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 92. 24 x 2.5 inch U.2 drives Gen5 Single Width
Order
1
2
3
4
5
6

PERC module

This is a service technician replaceable part only.

Removing the rear mounting front PERC module

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the cooling fan cage
From
SL4_CPU1_PB2 (signal connector on
system board)
SL2_CPU1_PB2 (signal connector on
system board)
SIG_PWR_1 (system board power
connector)
SL3_CPU1_PB2 (signal connector on
system board)
SL1_CPU1_PB2 (signal connector on
system board)
SIG_PWR_1 (system board power
connector)
Safety
instructions.
Before working inside your
assembly.
To
CTRL_DST_PB2 (fPERC input
connector)
CTRL_DST_PA2 (fPERC input
connector)
BP_PWR_2 (backplane power
connector)
CTRL_DST_PA1 (fPERC input
connector)
CTRL_DST_PA1 (fPERC input
connector)
BP_PWR_1 (backplane power
connector)
system.
Installing and removing system components
135