8.3

Description of service menu

Factory settings are printed in bold.
F1.2 – Digital filter
The digital filter stabilises the weight display when
0
Filter off
1
Filter setting low
2
Filter setting medium (factory setting)
3
Filter setting high
F1.5 – Tare operation
Tare operation can be enabled or disabled.
0
Tare function off
1
Tare function on (factory installation)
F1.6.2 – Auto zero operation
Zero setting within a set threshold value can be done automatically by the crane scale.
0
Automatic reset off (factory setting)
1
Automatic reset in +/–0.5 d area
2
Automatic reset in +/-1.0 d area
3
Automatic reset in +/-3 d area
F1.6.3 – Auto zero with power up
When the crane scale is powered up it will re-zero based on the tolerances below.
0
Automatic reset off when switching on (factory setting)
1
Automatic reset when switching on in +/–2% area
2
Automatic reset when switching on in +/-10 % area
3
Automatic reset when switching on in +/-100 % area
52