Test passed
Test failed
If the first pressure test failed an the second is OK, the fixture complies with IP65 integrity.
If the pressure test twice fails despite checking of correct tightening of the cover screws and gaskets under covers,
the fixture has to be tested by means of "Enhanced pressure test". For this type of pressure test is needed the
Pressure IP Testing Set ROBE (P/N 10980659). Please ask your ROBE distributor for help.
The message "Valve Seal Error" means that valve or coil in the valve is defective or there is a connection
problem.
Check the connection between the valve and head, especially cable connector. Other reason can be faulty coil
in the valve or faulty valve.
Cable connector
16
Valve