Fixtures must be installed by a qualified electrician in accordance with all
national and local electrical and construction codes and regulations.
The Robin iSpiider´s panel connectors are dust and water protected according to IP 65
by mating with related cable connectors. They cannot stay disconnected outdoor.
All unused panel connectors have to be sealed by the rubber caps.
Visually check panel connectors on accidental water leaks before connecting related
If some water will appear in panel connectors, do not connect cable connectors,
4.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The fixture has to be connected to an electric outlet which is equipped with
a residual-current device (residual-current circuit breaker)!
The Robin iSpiider is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 100-240
The IP65 rated power cable is enclosed to the fixture. If you need to install a power plug on the power cable
to allow connection to power outlets, install a grounding-type (earthed) plug, following the plug manufacturer's
instructions. If you have any doubts about proper installation, consult a qualified electrician.
The cores in the power cable are coloured according to the following table.
Core (EU)
Brown
Light blue
Yellow/Green
This device falls under class one and must be earthed (grounded)!
Ensure all connections and the power plug on the cable are properly sealed.
To apply power, first check that the head pan and tilt locks are released.
4. Installation
cable connectors.
especially power!
The rubber caps have to be placed on unused connectors.
Volts.
Core (US)
Black
White
Green
Connection
Plug Terminal Marking
Live
L
Neutral
N
Earth
7