Dalsa PC-30-02K80-R Manual page 89

Piranha color trilinear camera
Table of Contents

Advertisement

Piranha Color Camera User's Manual
Message
Error 04: Incorrect
parameter value>
Error 05: Command
unavailable in this
mode>
Error 06: Timeout>
Error 07: Camera
settings not saved>
Error 08: Unable to
calibrate - tap
outside ROI>
DALSA
Description
This error is returned for:
- Alpha character received instead of numeric character or visa versa.
- Float where integer expected.
- Not an element of the set of possible values. E.g., Baud Rate.
- Outside the range limit
E.g. Set sync frequency (ssf) when in external sync mode 3 (sem).
Command not completed in time. E.g. CCF or CCP in SEM 3 when
no external EXSYNC is present.
Indicates that user settings have been corrupted by turning off the
power while executing the WUS command. Must build up new settings
from factory and re-save with WUS.
Also present during manufacturing before settings saved for first time.
Cannot calibrate a tap that is not part of the end of line statistics.
03-032-10211-03
89
9/27/2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc-30-02k60-rPc-30-04k80-rPc-30-04k60-r

Table of Contents