Levelling the machine

Ensure that the machine feet and the installation surface are dry to
prevent the machine from slipping during the spin cycle.
Incorrect installation may increase electricity and water consumption
and may cause the machine to move about.
The four adjustable feet are used to level the washing machine. All
four feet are screwed in when the appliance is delivered.
Using the open spanner supplied, turn the counter nut (2) in a
clockwise direction. Then turn the counter nut (2) together with the
foot (1) to unscrew.
Use a spirit level to check the machine is standing level.
Hold the foot (1) securely with a pipe wrench. Turn the counter
nut (2) again using the open spanner supplied until it sits firmly up
against the casing.
The counter nuts must sit firmly up against the casing. Please also
check this for the feet which did not need adjustment. Otherwise
there is the danger of the washing machine moving about.

Water connection

The flow pressure must amount to a minimum of 100 kPa and must
not exceed 1000 kPa. If the flow pressure is higher than 1000 kPa, a
pressure reducing valve must be used.