Using the Transmitter
7.3

Viewing process variables

Process variables include measurements such as mass flow rate, volume flow rate, mass total, volume
total, temperature, and density.
You can view process variables with the display (if your transmitter has a display), ProLink II, or a
DeviceNet tool.
Note: If the petroleum measurement application is enabled, two of the API process variables are
averages: Batch Weighted Average Density and Batch Weighted Average Temperature. For both of
these, the averages are calculated for the current totalizer period, i.e., since the last reset of the API
volume totalizer.
7.3.1

With the display

By default, the display shows the mass flow rate, mass total, volume flow rate, volume total,
temperature, density, and drive gain. If desired, you can configure the display to show other process
variables. See Section 8.9.5.
The LCD panel reports the abbreviated name of the process variable (e.g.,
current value of that process variable, and the associated unit of measure (e.g.,
Appendix D for information on the codes and abbreviations used for display variables.
To view a process variable with the display:
If Auto Scroll is enabled, wait until the desired process variable appears on the LCD panel.
If Auto Scroll is not enabled,
-
Appears on the process variable line, or
-
Begins to alternate with the units of measure
See Figure 3-2.
The display precision can be configured separately for each process variable (see Section 8.9.5). This
affects only the value shown on the display, and does not affect the actual value as reported by the
transmitter via digital communications.
Process variable values are displayed using either standard decimal notation or exponential notation:
Values smaller than 100,000,000 are displayed in decimal notation (e.g.,
Values greater than 100,000,000 are displayed using exponential notation (e.g.,
-
If the value is less than the precision configured for that process variable, the value is
displayed as
-
If the value is too large to be displayed with the configured precision, the displayed
precision is reduced (i.e., the decimal point is shifted to the right) as required so that the
value can be displayed.
7.3.2

With ProLink II

The Process Variables window opens automatically when you first connect to the transmitter. This
window displays current values for the standard process variables (mass, volume, density,
temperature, external pressure, and external temperature).
To view the standard process variables with ProLink II, if you have closed the Process Variables
window, click
To view API process variables (if the petroleum measurement application is enabled), click
API Process Variables
36
(i.e., there is no exponential notation for fractional numbers).
0
ProLink > Process Variables
.
until the name of the desired process variable either:
Scroll
.
Micro Motion
for density), the
DENS
G/CM3
). See
1234567.89
®
Model 2400S Transmitters for DeviceNet
).
).
1.000E08
ProLink >