Menu Flowcharts
Figure B-3
ProLink II configuration menu
Display
· Var1
· Var2
· ...
· Var 15
Display precision
· Var
· Number of decimals
Display options
· Display start/stop totalizers
· Display totalizer reset
· Display auto scroll
· Display offline menu
· Display offline password
· Display alarm menu
· Display ack all alarms
· Display back light on/off
· Offline password
· Auto scroll rate
· Update period
· Backlight intensity
· Display language
(2)
API setup
· Table type
· Units
138
continued
ProLink >
Configuration
Transmitter options
· Meter fingerprinting
· Cryogenic modulus
compensation
· Meter verification
Discrete events
Discrete input
· Event name
· Start sensor zero
· Event type
· Reset mass total
· Process variable
· Reset volume total
· Low setpoint
· Reset all totals
· High setpoint
· Start/stop all totalization
· Reset gas standard volume total
· Reset API reference volume total
· Reset ED reference volume total
· Reset ED net mass total
· Reset ED net volume total
· Increment current ED curve
(3)
ED setup
Global config
· Active curve
· Derived variable
· Lock/unlock ED curves
Curve specific config
· Curve configured
· Curve name
· Reference temperature
· Water reference temperature
· Water reference density
· Trim slope
· Trim offset
Extrapolation
· Alarm limit
· Enable density low
· Enable density high
· Enable temperature low
· Enable temperature high
Concentration
· Units
· Special unit string
Alarm
· Alarm
· Severity
(1)
(3)
ED curve
Process fluid density at specified temperature
and concentration
· Curve being configured
· Curve fit max order
· Temperature isotherms
· Concentration
Curve fit results
· Accuracy
Process fluid density at reference temperature
and specified concentration
· Reference temperature
· Concentration
(1) Used to assign events to actions, even though the
Model 2400S DN transmitter does not provide a
discrete input.
(2) Available only if the petroleum measurement
application is installed.
(3) Available only if the enhanced density application is
installed.
®
Micro Motion
Model 2400S Transmitters for DeviceNet
Sensor simulation
Enable simulation mode
Mass flow
· Wave form
· Fixed value
· Period
· Minimum
· Maximum
Density
· Wave form
· Fixed value
· Period
· Minimum
· Maximum
Temperatuare
· Fixed value
· Period
· Minimum
· Maximum