Technical Data - ATH-Heinl 55HAP Manual

4-post lift
Hide thumbs Also See for 55HAP:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 74
1.5

Technical data

Type
Load capacity free lift
Load capacity
Time for lifting process (2000 kg)
Time for lowering (2000 kg)
Electrical system
Control voltage
Motor
Upstream fuse
Connection cable
Protection class
Working pressure
2
Recommended hydraulic oil
Oil quantity
Ground anchoring
Anchor quantity
Recommended air pressure
Permissible sound value
Weight
Warning
The factory-set working pressure is adjusted to the maximum nominal load. The pressure
2
relief valve must not be tampered with.
Changing the setting can lead to serious damage.
Note
If the specified nominal load cannot be raised, please contact our service team.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
ATH Four Lift 55HAP
3500 kg
5500 kg
45 s
42 s
3/400V/50Hz
DC 24 V
4 KW
3 C 16 A
Min. 5 x 2,5m
IP 43
Approx. 190 bar
Summer (10° to 45°): HVLP-D 46 (e.g.: Eni PRECIS HVLP-D)
Winter (below 10°): HVLP-D 32 (e.g.: Eni PRECIS HVLP-D)
Approx. 18 l
Bolt anchor: M16 x 180 (e.g.: Atrion ABL-W 16-060-180)
Composite anchor: M16 x 190 (e.g.: Atrion AVA-W 16-045-190)
16 pieces
8 bar
≤ 76 dB
2301 kg
Release date: 16.03.2023 / Product manufacturer ATH-Heinl GmbH & Co. KG
2
81